Frequently Asked Questions

Common (2)
LCR Meters (10)
Software (24)

Calibrators

  • How can I measure direct current strength using built-in 24 V power supply when operating AKTAKOM AM-7070 calibrator?
  • How can I display direct current strength (DC mA) when operating AKTAKOM AM-7070 calibrator?
  • How can I display DC voltage (OUTPUT DC V) when operating AKTAKOM AM-7070 calibrator?
  • Does AKTAKOM AM-7070 voltage and current calibrator have auto power off function?
  • How can I deactivate Auto Power Off function of AKTAKOM AM-7025 process calibrator?
  • Does AKTAKOM AM-7025 process calibrator have auto power off function?
  • Does AKTAKOM AM-7111 process calibrator have auto power off function?
  • Can I change the temperature unit when working with AM-7111?
  • How can I set the backlight time of AM-7111 calibrator?
  • Can I set auto power-off time when operating AM-7111 calibrator?

  • How can I measure direct current strength using built-in 24 V power supply when operating AKTAKOM AM-7070 calibrator?
    1. Press power switch, turn on AKTAKOM AM-7070 calibrator
    2. Press input/output conversion key to enter measurement mode (you will see INPUT indicator on the display).
    3. Press mA/mA% conversion key, make it indicate mA or mA%.
    4. Connect the red test lead to +LOOP, the black one to mA jack.
    5. Connect the red test lead to the positive input of the current source under test, the black one to the negative one
    6. The measured value will be shown in the main area of the display.

    Note: in this mode the device simultaneously outputs 24 V direct voltage on +LOOP and mA jacks and measures the input current from the external power supply under test.


    Up

    How can I display direct current strength (DC mA) when operating AKTAKOM AM-7070 calibrator?
    1. Press power switch, turn on AKTAKOM AM-7070 calibrator
    2. Press input/output conversion key to enter output mode (you will see OUTPUT indicator on the display).
    3. Press mA/mA% conversion key, make it indicate mA or mA%.
    4. Press ▲/▼ keys to specify the required DC output value
    5. Connect the red test lead to +LOOP, the black one to V jack.
    6. Connect the red test lead to the positive input of the device under test, the black one to the negative one
    7. To change the current output signal value or the range you need to use ▲/▼ or mA/mA% keys.

    Up

    How can I display DC voltage (OUTPUT DC V) when operating AKTAKOM AM-7070 calibrator?
    1. Press power switch, turn on AKTAKOM AM-7070 calibrator
    2. Press input/output conversion key to enter output mode (you will see OUTPUT indicator on the display).
    3. Press V mV conversion key, make it indicate DC V or mV.
    4. Press ▲/▼ keys to specify the required voltage output value
    5. Connect the red test lead to V jack, the black one to COM jack.
    6. Connect the red test lead to the positive polarity of the device under test, the black one to the negative one (ground).
    7. To change the current output signal value or the range you need to use ▲/▼ or V/mV keys.

    Up

    Does AKTAKOM AM-7070 voltage and current calibrator have auto power off function?
    Yes, it does. There is Auto Power Off function in AM-7070: the device power automatically goes off if you do not use the device within 10 minutes. If you would like to continue the work press POWER button.

    Up

    How can I deactivate Auto Power Off function of AKTAKOM AM-7025 process calibrator?
    Enter “SPFC” additional settings mode of AM-7025 process calibrator. You will need to keep HOLD button pressed when powering on the device. The top right corner will display “SPFC” symbol. To deactivate auto power off function press MEASURE ON button in “SPFC” mode until you see “AP.OFF” on the display. (This function is displayed on default when entering the additional settings mode). Specify auto power off time from 0 to 60 minutes by using the second pair of ⇓/⇑ keys (if counting from right to left). Every time you press ⇓/⇑ you increase or decrease the interval by 10 minutes. If you keep one of these keys pressed you continuously change the value, however this value won’t exceed the max. limit and won’t become lower the min. one. To save the results press SOURCE ON button, “SAVE” symbol will be displayed for 1 second. To automatically switch auto power off function specify “0”.

    Up

    Does AKTAKOM AM-7025 process calibrator have auto power off function?
    Yes, it does. There is Auto Power Off function in AM-7025 when operating in the measurer mode: the device power automatically goes off if you do not use the device within 5 minutes. If you would like to continue the work press POWER button.

    Up

    Does AKTAKOM AM-7111 process calibrator have auto power off function?
    Yes, it does. There is Auto Power Off function in AM-7111 and it’s off on default.

    Up

    Can I change the temperature unit when working with AM-7111?
    1. Press START key, LCD will display TEM.U symbol on the upper part indicating temperature unit setting mode.
    2. Choose between °C and °F using ▲ / ▼.
    3. Press ON key, LCD will display SAVE symbol on the upper part for 1s.

    Up

    How can I set the backlight time of AM-7111 calibrator?
    1. Press START key LCD will display BL.OFF symbol on the upper part indicating backlight time setting mode.
    2. Set the time by using the pair of ▲ / ▼. And the unit is second.
      Each pair of ▲ / ▼ keys corresponds to each digit of the LCD reading. Each press of ▲ / ▼ key increases or decreases the digit. Increasing the digit from 9 or decreasing it from 0 causes the digit to overflow or underflow, allowing you to set the output value without interruption. Holding down ▲ / ▼ key continuously changes the digit. And the value won't change if it is increased or decreased to the Maxim or Minimum value. The setting range is confined within 0-3600 seconds.
    3. Press ON key, LCD will display SAVE symbol on the upper part for 1 sec.

    Tips: When the default value is 0, the backlight won't be off automatically except that you turn it off manually.


    Up

    Can I set auto power-off time when operating AM-7111 calibrator?
    1. Press START key, LCD will display AP.OFF symbol on the upper part indicating automatic power-off setting mode.
    2. Set the time within 0-60 minute range by using the second pair of ▲ / ▼ counting from right to left.
      Each press of ▲ / ▼ key causes 10 minute increments or 10 minute decrement with constant setting. Constant press of the key causes increments or decrement of the value in sequence. The value won’t change when reaching the maximum or minimum value. The time unit is minute.
    3. Press ON key, LCD will display SAVE symbol on the upper part for 1 s.

    Tips: Zero default value (0) represents no automatic power-off function.


    Up