Setup time
D.E.V.I.C.E. is an encyclopedia of terms used by manufacturers of test and measurement equipment. T&M Atlantic created this service to better explain the functionality of instruments it offers, and to highlight the latest developments in the world of measurement equipment. We are using such tools as animation to bring words and pictures to life and to create not just an understanding but also an appreciation for technology that goes into the design of every instrument.
D.E.V.I.C.E. on Request
If you are searching for a particular term or definition, please contact us and our engineers will be glad to explain it to you.
Setup time is minimal time for the data set and stability before the appearance of the clock pulse rising edge.
The setup time example of the microcircuit recommended by manufacturers is shown in the table below:
Logic | Clock rate | Setup time | Hold time |
Altera Max 7000 PLD | 200 MHz | 2.5 ns | 0.5 ns |
Lattice GAL22V10-7 PAL | 133 MHz | 4.5 ns | 0 ns |
TI TMS320C549-40 DSP | 80 MHz | 5 ns | 0 ns |
Motorola MCM69D536 SRAM | 66 MHz | 3 ns | 1 ns |
Motorola MPC 860 Comm Controller | 50 MHz | 4 ns | 2 ns |
IDT 72420L20 Synchronous FIFO | 50 MHz | 5 ns | 1 ns |
Motorola Coldfire MCF 5206 Microcontroller | 33 MHz | 3 ns | 3 ns |
Motorola MC68332 Microcontroller | 16 MHz | 5 ns | 0 ns |
AMD 29DL800B Flash Memory | 16 MHz | 35 ns | 0 ns |
TI FN74LVC573A Octal Latch | n/a | 2 ns | 1.5 ns |