P2300B Oscilloscope Probe 300 MHz 10x
P2300B Oscilloscope Probe 300 MHz 10x
P2300B passive oscilloscope probe can be used together with any test instrument that has an input impedance of 1 MOhm and whose input capacitance is within the compensation range (see specifications).
For an accurate indication of the measuring signal, it is necessary to adjust the capacitance of the probe to the input capacitance of the oscilloscope. For this purpose the probe has an adjustment screw in the handling section. Learn more about probe compensation.
Specifications
- Attenuation ratio: 10:1
- Bandwidth: 0...300 MHz
- Rise time: 1.15 ns
- Input impedance: 10 MOhm ±1%
- Input capacitance: 16 pF
- Compensation range: 10 pF...30 pF
- Max. input voltage: 600 V DC+ACpk
- Lead length: 1.3 m
- Operating temperature: -10...+50 °C
- Non-operating temperature: -20...+75 °C
- Humidity: ≤85% RH
- Rated voltage when using touch-protected test instrument: max. 1000 V, CAT II; 600 V, CAT III (learn more about measurement categories)
Included Accessories
- Reference lead with crocodile clip
- Push-on hook clip
Back to the section
|
|
|
|