AKTAKOM ATA-2504 is a clamp meter-adapter. If you connect it to a multimeter the measurement results will be displayed on the display of this multimeter. In case of connecting ATA-2504 to an oscilloscope you will be able of researching a signal waveform.
DC Current (DCA)
200 A
AC Current (ACA)
200 A
Jaw size
0.9 in / 23 mm
Specifications:
Three ranges (4 A, 40 A, 200 A) in every measurement mode (AC/DC)
Output signal: from 1 to 100 mV, 1 A (AC/DC)
Frequency range: 40 Hz...1 kHz
Hall effect sensor
2 batteries: 1.5V, AA-type
Dimensions: 7.2 x 2.4 x 1.4 in / 183 x 61 x 36 mm
Weight: 6.7 oz / 190 g
Direct current
Range
Output
Accuracy
Sensitivity
0...4 A*
100 mV/A
±(0.02 + 0,005 A)
0.1 mV/1 mA
0...40 A
10 mV/A
±(0.01 + 0,02 A)
0.1 mV/10 mA
0...150 A
1 mV/A
±(0.01 + 0,2 A)
0.1 mV/100 mA
150...200 A
1 mV/A
±(0.022 + 0,2 A)
0.1 mV/100 mA
* at the range of 4 A the output voltage can vary within 0.4 mV
Alternating current (with 40 Hz...1 kHz frequency)
Range
Output
Accuracy
Sensitivity
0...4 A
100 mV/A
±(0.02 + 0.005 A)
0.1 mV/1 mA
0...40 A
10 mV/A
±(0.015 + 0.03 A)
0.1 mV/10 mA
0...150 A
1 mV/A
±(0.015 + 0.3 A)
0.1 mV/100 mA
150...200 A
1 mV/A
±(0.022 + 0.2 A)
0.1 mV/100 mA