DP-50 Differential Probe

 DP-50 Differential Probe
Click an image to enlarge

Retail price :$295.00

Depending on a destination shipping cost may vary.
Free shipping for orders over $450
on items weighting under 20 lbs
(certain restrictions apply!)

See shipping page for international rates
or contact sales@tmatlantic.com

In stock

BuyAdd to cart

The DP-50 differential probe provides a safety means for measuring differential voltage for all models of oscilloscopes.

The DP-50 converts high differential voltage into low voltage and displays the result on the oscilloscope screen. DP-50 is designed to operate with 1MΩ impendance oscilloscopes. When combining with the 50Ω load, the attenuation will be 2 times.

Specifications

  • Bandwidth: DC to 50 MHz (-3 dB)
  • Attenuation: x100, x200, x500, x1000
  • Accuracy: 2%
  • Voltage Input Ranges (DC + AC peak to peak)
    • ≤700 Vp-p for x100, (about 230 Vrms or DC)
    • ≤1400 Vp-p for x200, (about 460 Vrms or DC)
    • ≤3500 Vp-p for x500, (about 1140 Vrms or DC)
    • ≤7000 Vp-p for x1000, (about 2300 Vrms or DC)
  • Permitted Max Input Voltage
    • Max differential voltage: 7000 V (DC + AC peak to peak)
    • Max voltage between each input terminal and ground: 6500 Vrms
  • Input Impedance:
    • Differential: 16 MΩ / 1 pF
    • Between terminals and ground: 8 MΩ / 2 pF
  • Output: ≤7.0 V
  • Output Impedance: 50 Ω
  • Rise Time: 7 ns
  • Rejection Rate on Common Mode:
    • 60 Hz: > 80 dB
    • 100 Hz: > 60 dB
    • 1 MHz: > 50 dB
  • External 9 V DC power supply
  • Consumption: < 300 mA max
  • Operating Temperature / Relative Humidity: 0C ... +50C / 10 % ... 85 % RH
  • Storage Temperature / Relative Humidity: -30C ... +70C / 10 % ... 90 % RH
  • Dimensions: 9.45 x 3.15 x 1.18 in / 240 x 80 x 30 mm
  • Weight: 280g
  • Electrical Safety to IEC 1010-1
    • Dual Insulation
    • Installation Category III
    • Degree of Pollution 2
    • Rated Voltage or Max Line-Earth: 6500 Vrms
  • An Insulated BNC/BNC lead, length 100cm
  • AC Adapter
  • High voltage IC clips
  • Banana to Banana high voltage plug
  • Alligator plug
  • Test Lead
  • Carry Case
  • Instruction Manual

La sonda diferencial DP-50 ofrece una gran seguridad para la medicin de tensin diferencial para todos los modelos de osciloscopios.

El DP-50 convierte el voltaje diferencial de alta en baja tensin y muestra el resultado en la pantalla del osciloscopio. DP-50 est diseado para funcionar con 1MΩ osciloscopios impedancia. Cuando se combina con la carga de 50Ω, la atenuacin ser 2 veces.


Back to the section
Choose your clamp meter!
Site map|Privacy policy|Terms of Use & Store Policies|How to Buy|Shipping|Payment|© T&M Atlantic, Inc.,2010-2021