ATH-8030 Programmable Electronic Load
ATH-8030 Programmable Electronic Load
AKTAKOM ATH-8030 programmable electronic load is designed to work as a load when testing, configuring and adjusting power supplies, amplifiers and other electronic devices with a supply voltage of up to 150 V, a load current of up to 30 A, and an absorbed power of up to 300 W.
AKTAKOM ATH-8030 programmable electronic load (analog of M9712) provides great performance, reliability and ease of operation with high functionality. This electronic load supports different stabilization modes (constant voltage, constant current, constant resistance, constant power) as well as a number of test functions: battery test, dynamic test, external trigger.
Features
- VFD display
- Load operation modes: CV voltage regulation, CC current regulation, CR resistance regulation, CW power regulation, 2 combined modes: CC+CV, CR+CW
- Protection for current, voltage, power, overheating, reverse polarity
- Soft start function
- Battery testing
- Support for dynamic testing with rising and falling edge setting
- External Trigger Support
- Voltage drop compensation
- List work
- Automatic testing
- USB / RS-232 control
Specifications
Input Rating
|
Power
|
300W
|
Current
|
0-30A
|
Voltage
|
0-150V
|
CC Mode
|
Range
|
0-3A
|
0-30A
|
Resolution
|
0.1mA
|
1mA
|
Accuracy
|
0.03%+0.05%FS
|
0.03%+0.05%FS
|
CV Mode
|
Range
|
0.1-19.999V
|
0.1-150V
|
Resolution
|
1mV
|
10mV
|
Accuracy
|
0.03%+0.02%FS
|
0.03%+0.02%FS
|
CR Mode (Voltage and current input value >=10% full measurement)
|
Range
|
0.03-10K Oh
|
0.03-5K Oh
|
Resolution
|
16 bit
|
16 bit
|
Accuracy
|
0.1%+0.1%FS
|
0.1%+0.1%FS
|
CW Mode (Voltage and current input value >=10% full measurement)
|
Range
|
0-300W
|
0-300W
|
Resolution
|
1mW
|
10mW
|
Accuracy
|
0.1%+0.1%FS
|
0.1%+0.1%FS
|
Voltage Measurement
|
Voltage
|
0-19.999V
|
0-150V
|
Resolution
|
1mV
|
10mV
|
Accuracy
|
0.015%+0.03%FS
|
0.015%+0.03%FS
|
Current Measurement
|
Current
|
0-3A
|
0-30A
|
Resolution
|
0.01mA
|
0.1mA
|
Accuracy
|
0.03%+0.05%FS
|
0.03%+0.08%FS
|
Power Measurement (Voltage and current input value >=10% full measurement)
|
Power
|
100W
|
300W
|
Resolution
|
1mW
|
10mW
|
Accuracy
|
0.1%+0.1%FS
|
0.1%+0.1%FS
|
Battery Test
|
Battery Input: 0.1-150V; Max. Measurement: Capacity=999AH; Resolution=0.1mA; Test Time=1s-16h
|
Dynamic Test
|
Transition List: 0-25kHz; 2.5A/µs; T1&T2: 60µs-999s; Accuracy: +15% offset +10%FS
|
Current soft-startup Time
|
1ms; 2ms; 5ms; 10ms; 20ms; 50ms; 100ms; 200ms; 500ms; 1000ms; Accuracy:+15% offset+10%FS
|
Short Circuit
|
Current (CC)
|
=3.3A
|
=33A
|
Voltage (CV)
|
0V
|
Resistance (CR)
|
=35mOhm
|
Temperature
|
Operating
|
0~40°C
|
Nonoperating
|
-10°C~70°C
|
Dimension
|
WxHxD (mm)
|
214x108x365
|
Weight
|
kg
|
3.5
|
Back to the section
|
|
|
|