HY980D is a handheld high-end digital multimeter with clear LCD and the backlight for easy reading.
Multimeter is equipped with overload protection, low battery indication and auto-power off function.
This model is perfect for using in the field, workshop, for educational purposes and hobby.
General specifications:
Max voltage between terminals and earth ground: 1000V DC and 700V AC.
Fuse protection: 2A/250V
Operating altitude: 2000 meters (7000 ft.) max.
Over range indication: in that case “1” figure will be displayed.
Input impedance: 10MΩ
Overload protection:
200mV range: 250V DC or AC rms
2V-1000V ranges: 1000V DC or AC rms
Max. input voltage: 1000V DC
ACV:
Range
Resolution
Accuracy
2V
0.001V
± (0.8% + 3 digits)
20V
0.01V
± (0.8% + 3 digits)
200V
0.1V
± (0.8% + 3 digits)
750V
1V
± (1.2% + 3 digits)
Input impedance: 10MΩ
Overload protection:
200mV range: 250V DC or AC rms
2V-750V ranges: 700V DC or AC rms
Frequency range: 40 to 200Hz
Response: average, calibrated in rms of sine wave
Max. input voltage: 750V AC rma
DCA:
Range
Resolution
Accuracy
2mA
1µA
± (0.8% + 1 digit)
20mA
0.01mA
± (0.8% + 1 digit)
200mA
0.1mA
± (1.2% + 1 digit)
2A
1mA
± (1.2% + 1 digit)
20A
0.01A
± (2.0% + 5 digits)
Overload protection:
The fuse for this models is 2A/250V 20A range: unfused
ACA:
Range
Resolution
Accuracy
20mA
0.01mA
± (1.2% + 3 digits)
200mA
0.1mA
± (2.0% + 3 digits)
2A
1mA
± (2.0% + 3 digits)
20A
0.01A
± (3% + 7 digits)
Overload protection:
The fuse for this models is 2A/250V 20A range: unfused
Frequency range: 40~400Hz
Response: average, calibrated in rms of sine wave
Capacitance:
Range
Resolution
Accuracy
20nF
10PF
± (2.5% + 20 digits)
2µF
1nF
± (2.5% + 20 digits)
200µF
100nF
± (2.5% + 20 digits)
Open circuit voltage: approx. ACV 50mV
Overload protection: 250V DC or AC rms
Ohm:
Range
Resolution
Accuracy
200Ω
0.1Ω
± (0.8% + 3digits)
2kΩ
0.001kΩ
± (0.8% + 3digits)
20kΩ
0.01kΩ
± (0.8% + 3digits)
200kΩ
0.1kΩ
± (0.8% + 3digits)
2MΩ
0.001MΩ
± (0.8% + 3digits)
20MΩ
0.01MΩ
± (1.0% + 2digits)
Open circuit voltage: 0.25V
Overload protection: 250V DC or AC rms
Frequency test:
Range
Resolution
Frequency
20KHz
10Hz
± 1% ± 1 digit
Overload protection: AC 220V rms
HY980D es un multímetro digital de gama alta de mano con pantalla LCD clara y luz de fondo para una fácil lectura.
El multímetro está equipado con protección contra sobrecarga, indicación de batería baja y función de apagado automático.
Este modelo es perfecto para el uso en el campo, taller, con fines educativos y hobby.