The LCR meter AKTAKOM AMM-3320 is designed to measure Inductance (L), Capacitance (C), and Resistance (R). Mini USB port allows connecting the LCR meter to PC.
Depending on a destination shipping cost may vary. Free shipping for orders over $450 on items weighting under 20 lbs (certain restrictions apply!) See shipping page for international rates or contact sales@tmatlantic.comSold out
Subscribe
Description
Specifications
Accessories
Application
FAQ
Descripción
The LCR meter AKTAKOM AMM-3320 is designed to measure Inductance (L), Capacitance (C), and Resistance (R). Mini USB port allows connecting the LCR meter to PC.
The bellow-listed accuraies are guaranteed by the meter with normal use under the operating temperature of 18-28 and relative humidity less than 80%.
0.1 - 1Ω
1 - 10Ω
10Ω - 100kΩ
100kΩ - 1MΩ
1M - 20MΩ
20M - 200 MΩ
Remark
DCR
1.0% + 5d
0.5% + 3d
0.3% + 2d
0.5% + 3d
1.0% + 5d
2.0% + 5d
D<0.1
100 / 120 Hz
1.0% + 5d
0.5% + 3d
0.3% + 2d
0.5% + 3d
1.0% + 5d
2.0% + 5d
1 kHz
1.0% + 5d
0.5% + 3d
0.3% + 2d
0.5% + 3d
1.0% + 5d
5.0% + 5d
10 kHz
1.0% + 5d
0.5% + 3d
0.3% + 2d
0.5% + 3d
1.0% + 5d
N/A
100 kHz
2.0% + 5d
1.0% + 5d
0.5% + 3d
1.0% + 5d
2.0% + 5d (1M-2MΩ)
Frequency: 100 / 120 / 1k / 10k / 100kHz
Display: Dual display + analog bar display
Test level: 0.6Vrms
Rang mode: Auto and Hold
Equivalent Circuit: Parallel and Series
Calibration function: Open / Short
Interface: Mini-USB
Measurement speed: approx. 1.2 times / second
Measurement terminal: 4-terminal
Basic accuracy: 0.3%
Power: AAA*6 battery or external power supply
Auto power off: 5 min (with batteries)
Operation environment: temperature (0…40°C), humidity (90%RH, 40°C, no condensation)
Storage temperature: -25°C…50°C
Size: 8Ч4Ч2in / 203.2Ч101.6Ч 50.8mm
Weight: 20oz / 567g
LCR testing leads (pair)
LCR clips (open and short)
Black crocodile lead (single)
USB - mini cable
Batteries
Soft bag
User manual
Inductance measurement
Turn on the power.
There are two ways for inductance input:
a. Insert the measured inductance into the input terminal directly;
b. Connect the alligator clips to the ends of the measured inductance.
The default test mode is Auto LCR mode, the inductance value will show on primary display and the quality factor Q will show on secondary display. In Auto LCR mode, the D/Q/ESR key, SEL/PAL key, SORTING key and REL% key are not available.
Press FUNC. key to select Auto-L mode. The primary LCD display will show the inductance value. The secondary LCD display will show the quality factor Q. The equivalent resistance ESR/Rp, phase angle Θ or dissipation factor D can also be shown by pressing the D/Q/ESR key.
Press FREQ key to select frequency value: 100/120/1k/10k/100kHz.
Press SER/PAL key to select series or parallel mode.
Capacitance measurement
Turn on the power.
If exists voltage in the capacity, connect the two ends of the capacitor for a short time to discharge.
There are two ways for capacitance input:
a. Insert the positive polarity of capacitance into the positive terminal and its negative polarity into the negative terminal;
b. Insert the black and red testing lines with alligator clip into the "LCUR", "LPOT" terminal and "HCUR", "HPOT" terminal respectively. Connect the alligator clips to the two ends of capacitance corresponding to its polarity.
The default test mode is Auto LCR mode, the capacitance value will show on primary display and the dissipation factor D will show on secondary display. In Auto LCR mode, the D/Q/ESR key, SEL/PAL key, SORTING key and REL% key are not available.
Press FUNC. key twice to select Auto-C mode. The primary LCD display will show the capacitance value. The secondary LCD display will show the dissipation factor D. The quality factor Q, equivalent resistance ESR/Rp or phase angle θ can also be shown by pressing the D/Q/ESR key.
Press FREQ key to select frequency value: 100/120/1k/10k/100kHz.
Press SER/PAL key to select series or parallel mode.
Note: 1. When Auto-LCR mode is active, the secondary parameter will show the equivalent resistance in parallel mode (Rp) to replace the D factor if the C measured value is less than 5pF.
2. In order to avoid damaging the instrument, the capacitance requires discharge before measuring.
Resistance measurement
Turn on the power.
There are two ways for resistance input:
a. Insert the measured resistance into the input terminal directly;
b. Connect the alligator clips to the ends of the measured resistance.
The default test mode is Auto LCR mode, the resistance value will show on primary display and the phase angle θ will show on secondary display. In Auto LCR mode, the D/Q/ESR key, SEL/PAL key, SORTING key and REL% key are not available.
Press FUNC. key three times to select Auto-R (ACR) mode. The primary LCD display will show the resistance value. The secondary parameter is omitted and the D/Q/ESR key is not available.
Press FREQ key to select frequency value: 100/120/1k/10k/100kHz.
Press SER/PAL key to select series or parallel mode.
Press FUNC. key four times to select DCR mode. The primary LCD display will show the resistance value. The secondary parameter is omitted and the D/Q/ESR key, SEL/PAL key and FREQ key are not available.
Note: The phase angle Θ will show on secondary display only in Auto-LCR mode. During Auto-R mode or DCR mode, the secondary parameter is not available.
What is the purpose of AutoLCR mode in AKTAKOM AMM-3320 RLC Meter?
AutoLCR mode is used in AKTAKOM AMM-3320 RLC meter for automatic selection of the primary and secondary parameters for L, C, R modes and it is activated on default. Selection is made in accordance with the test result. This function makes it convenient to take measurements of different-type or unknown elements.
Condition
Primary parameter
Secondary parameter
lθl<-11°
Capacity (C)
Dissipation factor (D) (if C<5pF the secondary parameter is Rp)
How to select the secondary measured parameter when operating AKTAKOM AMM-3320 RLC Meter?
In order to select the secondary parameter when operating AKTAKOM AMM-3320 RLC Meter you need to press “D/Q/ESR” button. Each time you press the button the parameter changes in the following order: D (dissipation factor) ► Q (quality factor) ► θ (phase angle) ► ESR (equivalent series resistance)
How to select the primary measured parameter when operating AKTAKOM AMM-3320 RLC Meter?
In order to select the primary parameter when operating AKTAKOM AMM-3320 RLC Meter you need to press “FUNC” button. Each time you press "FUNC" the parameter changes in the following order: AUTO LCR (automatic selection of the value under measurement) ► L-Q (measurement of inductance and quality factor) ►C-D (measurement of capacity and dissipation factor) ►R (resistance measurement) ►DCR (DC resistance measurement).
L/C/R values can be positive and negative. If in C-D mode the primary parameter has "-" sign then the element should be measured in inductance mode. If in L-Q mode the primary parameter has "-" sign then the element should be measured in capacity mode. If in R mode the primary parameter is negative then this means calibration error and it is necessary to re-calibrate AMM-3320 RLC meter.
El multimetro LCR AKTAKOM AMM-3320 está diseñado para medir la inductancia (L), capacitancia (C), y la resistencia (R). Un puerto mini USB permite conectar el medidor LCR a la PC.
Características:
1,999 cuentas de doble pantalla LCD
Pantalla de barras analógica
Puerto Mini USB para conectar el PC
Auto LCR inteligente de verificación y medición
Parámetros Ls, Lp, Cs, Cp, DCR, ESR, D, Q y θ
Precisión básica: 0,3% con una resolución de 0,01%
Medición de frecuencia de hasta 100 kHz
Función de clasificación
Medida relativa
Retención de datos
Luz de fondo, el ángulo completo de la pantalla LCD