Multifunctional clamp meter for measurement of active, reactive and full power values in three-phase circuit of three- or four wires, balanced termination three-phase circuit, one-phase circuit of two- or three wires
Depending on a destination shipping cost may vary. Free shipping for orders over $450 on items weighting under 20 lbs (certain restrictions apply!) See shipping page for international rates or contact sales@tmatlantic.comSold out
Subscribe
Description
Specifications
Accessories
Application
FAQ
Descripción
AKTAKOM ATK-2209 is a multifunctional clamp meter which allows you to measure the value of active, reactive and full power in three-phase circuit of three- or four wires, balanced termination three-phase circuit, one-phase circuit of two- or three wires.
"Absolute measurement error" service allows you to estimate the measurement accuracy considering uncertainty (error) in the absolute value. It's important if you take measurements at the range edge when the error value contributes to the value displayed on the device screen.
To get the value range it'd be enough to enter the estimate of the value under measurement into Value input field and to see the range of possible values taking all of the standardized errors into consideration.
Note: a point is used as a separator of the integer and fractional part.
DC Voltage
Range
Resolution
Accuracy
Absolute error
Value-error
Value
Value+error
999.9 mV
0.1 mV
±(1%+20 digits)
±11.998 mV
mV
9.999 V
1 mV
±(1%+20 digits)
±0.11998 V
V
99.99 V
10 mV
±(1%+20 digits)
±1.1998 V
V
600 V
100 mV
±(1%+20 digits)
±7.999 V
V
AC Voltage
Range
Resolution
Accuracy
Absolute error
Value-error
Value
Value+error
999.9 V
0.1 mV
±(1%+20 digits)
±10.000999 V
V
9.999 V
1 mV
±(1%+20 digits)
±0.11998 V
V
99.99 V
10 mV
±(1%+20 digits)
±1.1998 V
V
600 V
100 mV
±(1%+20 digits)
±7.999 V
V
AC Current
Range
Resolution
Accuracy
Absolute error
Value-error
Value
Value+error
99.99 A
10 mA
±(2%+20 digits)
±2.1996 A
A
999.9 A
100 mA
±(2%+20 digits)
±21.996 A
A
Frequency
Range
Resolution
Accuracy
Absolute error
Value-error
Value
Value+error
100 kHz
0.1 Hz
±(0.5%+2 digits)
±0.5001995 kHz
kHz
Resistance
Range
Resolution
Accuracy
Absolute error
Value-error
Value
Value+error
999.9 Ω
100 mΩ
±(1%+10 digits)
±10.998 Ω
Ω
9.999 kΩ
1 Ω
±(1%+10 digits)
±0.10998 kΩ
kΩ
99.99 kΩ
10 Ω
±(1%+10 digits)
±1.0998 kΩ
kΩ
999.9 kΩ
100 Ω
±(1%+10 digits)
±10.998 kΩ
kΩ
9.999 MΩ
1 kΩ
±(5%+10 digits)
±0.5099 MΩ
MΩ
99.99 MΩ
10 kΩ
±(5%+10 digits)
±5.099 MΩ
MΩ
Capacitance
Range
Resolution
Accuracy
Absolute error
Value-error
Value
Value+error
10 µF
1 nF
±(1.5%+5 digits)
±0.154985 µF
µF
100 µF
10 nF
±(1.5%+5 digits)
±1.54985 µF
µF
1000 µF
100 nF
±(1.5%+5 digits)
±15.4985 µF
µF
7000 µF
1 µF
Unspecified
Unspecified
µF
Active power
Range
Resolution
Accuracy
Absolute error
Value-error
Value
Value+error
60 kW
0.01 kW
±(5%+20 digits)
±3.1995 kW
kW
600 kW
0.1 kW
±(5%+20 digits)
±31.995 kW
kW
Reactive power
Range
Resolution
Accuracy
Absolute error
Value-error
Value
Value+error
60 kVA
0.01 kVA
±(5%+20 digits)
±3.1995 kVA
kVA
600 kVA
0.1 kVA
±(5%+20 digits)
±31.995 kVA
kVA
Apparent power
Range
Resolution
Accuracy
Absolute error
Value-error
Value
Value+error
60 kVA
0.01 kVA
±(2.5%+20 digits)
±1.69975 kVA
kVA
600 kVA
0.1 kVA
±(2.5%+20 digits)
±16.9975 kVA
kVA
Specifications:
AC/DC voltage measurement: 2 mV...600 V, resolution from 0.1 mV
Input impedance: 3 MΩ
Alternating current measurement: 10 mA...1000 A (40...400 Hz)
Direct current measurement: 0.20 µA...1000 µA
Current and voltage True RMS measurement
Active, reactive and full power measurement in one- and three-circuits at the range of up to 600 kW, resolution from 10 W.
Power factor calculation: cos φ
Resistance measurement: 0.1 Ω...100 MΩ, resolution from 0.1 Ω
Frequency measurement: 40 Hz...1 kHz, resolution: 0.1 Hz
Capacity measurement: up to 7000 µF, resolution from 1 nF
Temperature measurement (K-type thermocouple) –50...900 °C
Simultaneous displaying of 2 parameters
Data hold, hold of min./max. values
Auto selection of measurement limits
4 digit display
Display auto power off
Battery low charge indication
Overload indication
Current consumption: 25 mA
Battery: 9V
Operation temperature: 41…104 °F / 5...40 °Ñ
Grip diameter: 1.7 in / 42 mm
Dimensions: 9.7 x 3.4 x 1.6 in / 247 x 87 x 40 mm
Weight: 1.03 lb / 465 g
Connecting leads (red and black)
Alligator clips
Battery
Carrying case
User manual
AKTAKOM ATK-2209 es un medidor de pinza multifuncional que le permite medir el valor de potencia activa, reactiva y plena en un circuito trifásico de tres o cuatro cables, circuito trifásico de terminación balanceada, circuito monofásico de dos o tres cables