Type M thermocouple

Type M thermocouples use a nickel alloy for each wire. The positive wire (20 Alloy) contains 18% molybdenum while the negative wire (19 Alloy) contains 0.8% cobalt. These thermocouples are used in vacuum furnaces for the same reasons as with type C. Upper temperature is limited to 1400°C / 2552°F. It is less commonly used than other types.

www.wikipedia.org


Back to the list

Search by section D.E.V.I.C.E. services

Measurement History Events
Yesterday Today Tomorrow
04/20/1904
date of birth
Stibitz, George

Units Converter

AKTAKOM - the Best in Test Award Winner!
Site map|Privacy policy|Terms of Use & Store Policies|How to Buy|Shipping|Payment|© T&M Atlantic, Inc., 2010-2024