New AKTAKOM ADS-4222 Handheld Digital Oscilloscope is 3-in-1 meaning it combines oscilloscope, DMM and datalogger functions. It can be used for different measurement tasks connected with field test, service support. This model is perfect for the use in research laboratories and educational institutions. New oscilloscopes have such advantages and innovative technical features which do not pertain to some other well-known brands.

Features

  • Three isolated inputs include two oscilloscope inputs and one multimeter input, and all isolated inputs allow independent floating measurements with each input

  • Three operation modes for moving waveform, zooming in and out, and using menu by touch, button and scroll wheel

  • 5.6" TFT LCD touch screen, 640 * 480 high resolution

  • Memory depth: 240 Kpts
  • Waveform capture rate: up to 190 000 wfms/s

  • Auto (23 types) and cursor measurements in oscilloscope mode

  • Math operation (*, /, -, +) and FFT window settings (4 windows)

  • Trigger type: edge, pulse, logic, serial bus (UART,LIN,CAN,SPI,I2C)

  • 3 types of record modes: multimeter record, oscilloscope measurement record and oscilloscope waveform record

  • Shockproof housing
  • Weight 1,4 kg / 3 pounds

Channels2
Bandwidth200 MHz
Sample rate1 GSa/s
Memory depth240 Kpts
Vertical resolution (bits)8
Trigger typesEdge trigger, Pulse width trigger, Logic trigger, Serial bus trigger
Number of automatic measurements31
Automatic measurementVpp, Vmax, Vmin, Vtop, Vbase, Vamp, Vavg, Vrms, Crms (Cycrms), Mean, Overshoot, PREShoot, Frequency, Period, Rise Time, Fall Time, +Duty, -Duty, +Wid, -Wid, Delay A→B, Phase, BWid
Waveform mathAddition (+), Subtraction (-), Multiplication (*), Division (/), FFT (fast Fourier transform)
Special featuresTouch screen, Isolated inputs, Digital multimeter
InterfaceUSB Host, USB Device
Display5.7" TFT (640 x 480)
Power supply100...240 VAC, battery
Dimensions254 x 160 x 60 mm / 10 x 6.3 x 2.4 in

 Specifications:

Vertical system:

  • Channels: 2 oscilloscope channels (isolated),1 multimeter channel (isolated)
  • Limited bandwidth: 20MHz
  • Coupling modes: DC,AC,GND
  • Input impedance: parallel 1MΩ±1% with 15pF±3pF
  • Vertical scale: 5mV/div~50V/div
  • Vertical resolution: 8 bits
  • DC vertical gain accuracy: 5mV/div~50V/div,2.0%

Horizontal system:

  • Timebase: 4ns/div~10s/div
  • Timebase delay range: -12divs~50s
  • Timebase accuracy: 20ppm
  • Sample mode: normal,average, pk-pk,envelope
  • Dynamic record: - (can be upgraded)
  • Store waveform: 4 ref waveforms (can be upgraded to flash disk storage)

Trigger system:

  • Trigger types: edge, pulse, logic, serial bus(UART,LIN,CAN,SPI,I2C)
  • Trigger coupling: DC,AC,High-frequency suppression,Low-frequency suppression, Noise suppression
  • Trigger modes: auto, normal, single
  • Trigger scource: CH1,CH2
  • Inhibition range: 200ns~10s

Math:

  • Operator: + , - , * , /
  • FFT window settings: Rectangular, Hamming, Blackman-Harris, Hanning

DMM:

  • Measurement types: 9 physical measurements such as voltage, current, resistance, capacitance, diode , etc. including temperature, relative humidity, atmospheric pressure
  • Measuremet accuracy: 4 bits
  • Measurement display: max, average, min, values with time stamp,relative measurement

Datalogger:

  • Logger content: multimeter measurements, oscilloscope waveform, oscilloscope measurements
  • Logger timebase: multimeter measurements,10s/div ~ 20min/div; oscilloscope measurements 10s/div ~ 20min/div
    oscilloscope waveform 100us/div ~ 2min/div
  • Logger time length: max 17 days

Power:

  • Power adapter: input:100-240VAC,50-60Hz,2A; output:12VDC,5A
  • Battery: capacity: 7.4V/6000mAh, work time:4~5 hours
  • Battery
  • USB Adapter
  • Cord
  • Power Cord
  • Probes

Frequently Asked Questions

  • When changing the horizontal sweep on the digital oscilloscope at different horizontal points observed inexplicable change in the form of the same signal, why is this happening?
  • There is wave form displayed, but it is not stable

  • When changing the horizontal sweep on the digital oscilloscope at different horizontal points observed inexplicable change in the form of the same signal, why is this happening?

    In fact, this is not a problem.

    Just keep in mind that you're using a digital oscilloscope, which digitizes the signal with different sampling rates depending on the selected horizontal sweep, and then connects the digitized points with strait line while restoring the real shape of the signal.

    Your first screen shows that you are measuring voltage 50 Hz with the 10 ms / div sweep and a sampling frequency of 20 kHz Ks/s

    One signal period (20 ms), digitized in this mode, 20E-03 (sec) * 20E03 (1/sec) = 400 points. This is enough to properly restore and interpolate a sine wave of 50 Hz (i.e. in a period of 20 ms).

    Normal display, with a sweep 10 ms / div:

    Distortion of the same signal at 10 s / div sweep

    Your second screen is set to sweep 10 sec / div, and sample rate on a sweep turned to 20 samples per second (20 Sa / s). I.e. one signal period 20 ms had: 20E-03 (sec) * 20 (1/sec) = 0.4 points. That means that to restore (to interpolate the points) a sine wave with less than one point in time is impossible, so you get this mess (known as "aliasing" or a false frequency) formed by the beats of the measured frequency and sampling frequency.

    In order to correctly install a data collection in a digital oscilloscope one should follow a simple rule - the sampling rate must be at least 5-10 times higher than the frequency signal, in that case you will not have the issues that we just discussed.

    This applies to all digital oscilloscopes and in no way connected to any particular make or model of oscilloscope or its probes.


    Up

    There is wave form displayed, but it is not stable

    • Check whether the Source item in the TRIG MODE menu is in conformity with the signal channel used in the practical application.
    • Check on the trigger Type item: The common signal chooses the Edge trigger mode for Type and the video signal the Video. Only if a proper trigger mode is applied, the wave form can be displayed steadily.
    • Try to change the trigger coupling into the high frequency suppress and the low frequency suppress to smooth the high frequency or low frequency noise triggered by the interference.