ADS-4132D Handheld Digital Oscilloscope 100MHz 1GSa/s

AKTAKOM ADS-4132D Handheld Digital Oscilloscope 100MHz 1GSa/s
Click an image to enlarge
Brand: AKTAKOM
Warranty: 14 months
USB Host

Retail price : $1,999.00

Depending on a destination shipping cost may vary.
Free shipping for orders over $450
on items weighting under 20 lbs
(certain restrictions apply!)

See shipping page for international rates
or contact sales@tmatlantic.com

Sold out

Subscribe
3-in-1: Oscilloscope + DMM + Datalogger

Bandwidth100 MHz
Sample rate1 GSa/s
Vertical resolution (bits)8
Trigger typesEdge trigger, Pulse width trigger, Logic trigger, Serial bus trigger
Number of automatic measurements31
Automatic measurementVpp, Vmax, Vmin, Vtop, Vbase, Vamp, Vavg, Vrms, Crms (Cycrms), Mean, Overshoot, PREShoot, Frequency, Period, Rise Time, Fall Time, +Duty, -Duty, +Wid, -Wid, Delay A→B, Phase, BWid
Waveform mathAddition (+), Subtraction (-), Multiplication (*), Division (/), FFT (fast Fourier transform)
Special featuresTouch screen, Digital multimeter
InterfaceUSB Host, USB Device
Display5.6" TFT (640 x 480)
Power supply100...240 VAC, battery
Dimensions254 x 160 x 60 mm / 10 x 6.3 x 2.4 in

3-in-1: Oscilloscope + DMM + Datalogger. Oscilloscope: bandwidth 100 MHz, 2 isolated channels, max sampling rate 1 GSa/s, record length 240 Kpts, vertical resolution 8 bit, volts/div range 5 mV/div - 50 V/div, time base range 4 ns/div - 10 s/div, 31 automatic measurements, cursor measurements, HDTV trigger, serial bus trigger (UART, LIN, CAN, SPI, I²C, MIL-STD-1553B, ARINC429), serial bus decoding, FFT. DMM: voltage (AC, DC, AC+DC), current (AC, DC), resistance, capacitance, temperature, relative humidity, continuity check, diode check; statistics (max., min., average), relative measurements. USB Device, USB Host, colour touch screen 5,7" (640x480), battery (7,4 V/6000 mAh). Dimensions 254 x 160 x 60 mm, weight 1,4 kg.

Frequently Asked Questions

  • When changing the horizontal sweep on the digital oscilloscope at different horizontal points observed inexplicable change in the form of the same signal, why is this happening?
  • There is wave form displayed, but it is not stable

  • When changing the horizontal sweep on the digital oscilloscope at different horizontal points observed inexplicable change in the form of the same signal, why is this happening?

    In fact, this is not a problem.

    Just keep in mind that you're using a digital oscilloscope, which digitizes the signal with different sampling rates depending on the selected horizontal sweep, and then connects the digitized points with strait line while restoring the real shape of the signal.

    Your first screen shows that you are measuring voltage 50 Hz with the 10 ms / div sweep and a sampling frequency of 20 kHz Ks/s

    One signal period (20 ms), digitized in this mode, 20E-03 (sec) * 20E03 (1/sec) = 400 points. This is enough to properly restore and interpolate a sine wave of 50 Hz (i.e. in a period of 20 ms).

    Normal display, with a sweep 10 ms / div:

    Distortion of the same signal at 10 s / div sweep

    Your second screen is set to sweep 10 sec / div, and sample rate on a sweep turned to 20 samples per second (20 Sa / s). I.e. one signal period 20 ms had: 20E-03 (sec) * 20 (1/sec) = 0.4 points. That means that to restore (to interpolate the points) a sine wave with less than one point in time is impossible, so you get this mess (known as "aliasing" or a false frequency) formed by the beats of the measured frequency and sampling frequency.

    In order to correctly install a data collection in a digital oscilloscope one should follow a simple rule - the sampling rate must be at least 5-10 times higher than the frequency signal, in that case you will not have the issues that we just discussed.

    This applies to all digital oscilloscopes and in no way connected to any particular make or model of oscilloscope or its probes.


    Up

    There is wave form displayed, but it is not stable

    • Check whether the Source item in the TRIG MODE menu is in conformity with the signal channel used in the practical application.
    • Check on the trigger Type item: The common signal chooses the Edge trigger mode for Type and the video signal the Video. Only if a proper trigger mode is applied, the wave form can be displayed steadily.
    • Try to change the trigger coupling into the high frequency suppress and the low frequency suppress to smooth the high frequency or low frequency noise triggered by the interference.

    Up

    Handheld digital oscilloscopes AKTAKOM ADS-4000 series


    Back to the section
     

    Please give us your feedback to help us improve our website