Español

AM-7070 Voltage and Current Calibrator

AKTAKOM AM-7070 Voltage and Current Calibrator
Click an image to enlarge
Brand: AKTAKOM
User's Guide: Download

High-end voltage and current calibrator designed to generate DC voltage and current regulated signal when adjusting and testing sensors and other equipment in various types of application

Retail price : $299.00

Depending on a destination shipping cost may vary.
Free shipping for orders over $450
on items weighting under 20 lbs
(certain restrictions apply!)

See shipping page for international rates
or contact sales@tmatlantic.com

In stock now

Buy Add to cart

High-end AKTAKOM AM-7070 voltage and current calibrator is the source of voltage and current calibrated values and it’s designed to generate DC voltage and current regulated signal when adjusting and testing sensors and other equipment in various types of application (repair service, oil and chemical industry, test laboratories, production and quality control, educational institutions).

AM-7070 has an additional function of voltage and current measurements (note: it can’t be used simultaneously with generation). Thus AM-7070 represents a universal electronic device to control and measure voltage and current.

DisplayLarge LCD: 5 gidit (2.5 x 1.7 in / 64 x 42 mm)
Dimensions8 x 3.9 x 1.8 in / 205 x 99 x 46 mm

Specifications:

  • DC voltage measurement (auto selection of the range):
    Range:
    0.01…110 mV
    0.001…15 V
    Inaccuracy: ±(0.02%+3)
  • DC voltage generation (manual selection of the range)
    Range:
    0.01…100 mV
    0.001…15 V
    Inaccuracy: ±(0.015%+3)
  • DC generation and measurement:
    Range: 0.001…24 mV
    Inaccuracy: ±(0.015%+3)
  • Current display in %: 0% = 4 mA; 100% = 20 mA
  • Loop supply:
    Range: 24 V
    Inaccuracy: ±10%
  • Large LCD: 5 gidit (2.5 x 1.7 in / 64 x 42 mm)
  • Protected test probes with double insulation
  • Input impedance: 2 MΩ; <100 pF
  • Voltage overload protection: 30 V
  • Current overload protection (high-performance fuse)
  • Power supply: batteries, 6x1, 5 V (triple-A)
  • Auto-power off: can’t be disabled
  • Dimensions: 8 x 3.9 x 1.8 in / 205 x 99 x 46 mm
  • Weight: appr. 1.1 lb / 500 g

Standard accessories:

  • Measurement probes – 2 pcs
  • Alligator clips – 2 pcs
  • Batteries: 1.5 V, triple-A – 6 pcs
  • Soft case
  • User manual

Simulating a Transmitter with AKTAKOM AM-7070 calibrator

  1. Press the power switch, turn on AKTAKOM AM-7070 calibrator.
  2. Press the input/output conversion key to enter output mode (you will see OUTPUT indicator on the display)
  3. Press mA mA% conversion key, make it indicate mA or mA%.
  4. Press ▲/▼ keys to specify the required DC output value
  5. Connect the red test lead to V jack, the black one to COM jack
  6. Connect the red test lead to the positive output of the external power supply, the black one to the positive terminal of the device under test
  7. To change the current output signal value or the range you need to use ▲/▼ or mA/mA% keys.

DC V measurement with AKTAKOM AM-7070 calibrator

  1. Press power switch, turn on AKTAKOM AM-7070 calibrator.
  2. Press input/output conversion key to enter the measurement mode (you will see INPUT indicator on the display)
  3. Press V mV conversion key, make it indicate VDC or mVDC.
  4. Connect the red test lead to V jack, the black one to COM jack.
  5. Connect the red test lead to the positive polarity of the device under measurement, the black one to the negative one (ground).
  6. The measured value will be shown in the main area of the display.

DC mA measurement with AKTAKOM AM-7070 calibrator

  1. Press power switch, turn on AKTAKOM AM-7070 calibrator
  2. Press input/output conversion key to enter the measurement mode (you will see INPUT indicator on the display)
  3. Press mA mA% conversion key, make it indicate mA or mA%.
  4. Connect the red test lead to mA jack, the black one to COM jack
  5. Connect the red test lead to the positive polarity of the device under measurement, the black one to the negative one.
  6. The measured value will be shown in the main area of the display.

Controls of AKTAKOM AM-7070 Voltage and Current Calibrator



Display of AKTAKOM AM-7070 Voltage and Current Calibrator

Frequently Asked Questions

  • How can I display direct current strength (DC mA) when operating AKTAKOM AM-7070 calibrator?
  • How can I measure direct current strength using built-in 24 V power supply when operating AKTAKOM AM-7070 calibrator?
  • How can I display DC voltage (OUTPUT DC V) when operating AKTAKOM AM-7070 calibrator?
  • Does AKTAKOM AM-7070 voltage and current calibrator have auto power off function?

  • How can I display direct current strength (DC mA) when operating AKTAKOM AM-7070 calibrator?

    1. Press power switch, turn on AKTAKOM AM-7070 calibrator
    2. Press input/output conversion key to enter output mode (you will see OUTPUT indicator on the display).
    3. Press mA/mA% conversion key, make it indicate mA or mA%.
    4. Press ▲/▼ keys to specify the required DC output value
    5. Connect the red test lead to +LOOP, the black one to V jack.
    6. Connect the red test lead to the positive input of the device under test, the black one to the negative one
    7. To change the current output signal value or the range you need to use ▲/▼ or mA/mA% keys.

    Up

    How can I measure direct current strength using built-in 24 V power supply when operating AKTAKOM AM-7070 calibrator?

    1. Press power switch, turn on AKTAKOM AM-7070 calibrator
    2. Press input/output conversion key to enter measurement mode (you will see INPUT indicator on the display).
    3. Press mA/mA% conversion key, make it indicate mA or mA%.
    4. Connect the red test lead to +LOOP, the black one to mA jack.
    5. Connect the red test lead to the positive input of the current source under test, the black one to the negative one
    6. The measured value will be shown in the main area of the display.

    Note: in this mode the device simultaneously outputs 24 V direct voltage on +LOOP and mA jacks and measures the input current from the external power supply under test.


    Up

    How can I display DC voltage (OUTPUT DC V) when operating AKTAKOM AM-7070 calibrator?

    1. Press power switch, turn on AKTAKOM AM-7070 calibrator
    2. Press input/output conversion key to enter output mode (you will see OUTPUT indicator on the display).
    3. Press V mV conversion key, make it indicate DC V or mV.
    4. Press ▲/▼ keys to specify the required voltage output value
    5. Connect the red test lead to V jack, the black one to COM jack.
    6. Connect the red test lead to the positive polarity of the device under test, the black one to the negative one (ground).
    7. To change the current output signal value or the range you need to use ▲/▼ or V/mV keys.

    Up

    Does AKTAKOM AM-7070 voltage and current calibrator have auto power off function?

    Yes, it does. There is Auto Power Off function in AM-7070: the device power automatically goes off if you do not use the device within 10 minutes. If you would like to continue the work press POWER button.
    Up


    Back to the section
     

    Please give us your feedback to help us improve our website

    * - required fields

    AKTAKOM AMM-4189 Digital Multimeter & Oscilloscope
    Site map|Privacy statement|Terms of Use & Store Policies|How to Buy|Shipping|Payment|© T&M Atlantic, Inc., 2010-2017