Clamp meter ACM-1010 is designed for non-contact alternate current measurement as well as AC/DC voltage, resistance and other measurements including temperature.

Features:

  • Audible continuity test
  • Manual range selection
  • Data hold button
  • Backligt LCD display

DC Voltage (DCV)1000 V
DCV Accuracy(1.0%+2)
DCV Resolution1 V
AC Voltage (ACV)750 V
ACV Accuracy(1.2%+5)
ACV Resolution1 V
AC Current (ACA)1000 A
ACA Accuracy(2.0%+5)
ACA Resolution0.01 A
Resistance0.1...2000 Ω
Temperature-40...+750 C
Continuity check+
Autorange+
Data hold+
Jaw size1.6 in / 42 mm
DisplayLCD, 1999 counts
Power supply3 x 1.5 V batteries
Dimensions8.9 x 3.4 x 1.3 in / 225 x 86 x 32 mm

Accuracy tables

DC Voltage

RangeResolutionAccuracyAbsolute errorValue-errorValue Learn an absolute error of your measurementValue+error
1000 V 1 V (1%+2 digits) 11.99 V V

AC Voltage

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
700 V 1 V (1.2%+5 digits) 13.388 V V

AC Current

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
20 A 0.01 A (2.0%+5 digits) 0.4498 A A
200 A 0.1 A (2.0%+5 digits) 4.498 A A
1000 A 1 A (2.5%+7 digits) 31.975 A A

Resistance

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
200 Ω 0.1 Ω (1.0%+3 digits) 2.299 Ω Ω
2000 Ω 1 Ω (1.0%+3 digits) 22.99 Ω Ω

Clamp meter ACM-1010 is designed for non-contact current measurement as well as AC/DC voltage, resistance and other measurements.

Specifications:

Function Ranges Basic Accuracy
Voltage DC 1000V (1.0%+2d)
Voltage AC 750V (1.2%+5d)
Current AC 20/200/1000A (2.0%+5d)
Resistance 200Ω/2kΩ (1.0%+3d)
Temperature -40C750C (1.0%+3d)

General features:

  • Range selection: manual
  • Data hold
  • Continuity check
  • Diameter of coverage: 42mm/1.7in
  • Display: LCD 1999 counts
  • Supply: 3x1.5V (AAA) 

General accessories:

  • Test leads
  • Temperature probe
  • User manual

Controls of AKTAKOM ACM-1010 Clamp Meter

Controls of AKTAKOM ACM-1010 Clamp Meter

DC Voltage Measurement

  1. Connect the red test lead to the "V/Ω" jack and the black lead to the "COM" jack.
  2. Set rotary switch at desired 1000V DC symbol position.
  3. Connect test leads across the source or load being measured.
  4. Read voltage value on the LCD display along with the polarity of the red lead connection.

DDC Voltage Measurement

AC Voltage Measurement

  1. Connect the red test lead to the "V/Ω" jack and the black lead to the "COM" jack.
  2. Set rotary switch at desired 750V ac symbol position.
  3. Connect test leads across the source or load being measured.
  4. Read voltage value on the LCD display.

ACV Measurement

AC Current Measurement

  1. Set the rotary switch at desired A position.
  2. Press the trigger to open transformer jaw and to clamp one conductor only, making sure that the jaw is firmly closed around the conductor.
  3. Read current value on LCD display.
  4. When only the figure "1" is displayed, it indicates overrange situation and the higher range has to be selected.

AC CURRENT MEASUREMENT

Resistance Measurement

  1. Connect the red test lead to "V/Ω" jack and black test lead to the "COM" jack (The polarity of red lead is positive "+").
  2. Set the rotary switch at desired "Ω" range position.
  3. Connect test leads across the resistor to be measured and read LCD display.
  4. If the resistance being measured is connected to a circuit, turn off power and discharge all capacitors before applying test probes.
NOTE:
  • If the resistance being measured exceeds the maximum value of the range selected or the input is not connected, an overrange indication "1" will be displayed.
  • When checking in-circuit resistance, be sure the circuit under test has all power removed and that all capacitors have been discharged fully.

Resistance Measurement

Continuity test

  1. Connect red test lead to "V/Ω" jack, black test lead to "COM" jack.
  2. Set range switch to "" position.
  3. Connect test leads to two points of circuit to be tested. If continuity exists, built-in buzzer will sound.

Continuity Test

Temperature Measurement

  1. Set the rotary switch at 750 °C position.
  2. Connect the red lead of “K” type thermocouple into the "V/Ω" jack and the black lead of "K" type thermocouple into the "COM" jack. The LCD display will show the current environment temperature.
  3. Contacting the object be measured with the thermocouple probe.
  4. Read temperature value on the LCD display.

Temperature measurement

Frequently Asked Questions

  • How to measure AC voltage using ACM-1010 AC clamp meter and thermometer?
  • How to measure AC current using ACM-1010 AC clamp meter and thermometer?
  • How to measure resistance using ACM-1010 AC clamp meter and thermometer?
  • How to make audible continuity test using ACM-1010 AC clamp meter and thermometer?
  • How to measure temperature using ACM-1010 AC clamp meter and thermometer?
  • How to measure DC voltage using ACM-1010 AC clamp meter and thermometer?

  • How to measure AC voltage using ACM-1010 AC clamp meter and thermometer?

    1. Connect the red test lead to “V/Ω” jack and the black test lead to the “COM” jack.
    2. Set the rotary switch at desired 750V~ position.
    3. Connect test leads across the source or load being measured.
    4. Read voltage value on the LCD display

    Up

    How to measure AC current using ACM-1010 AC clamp meter and thermometer?

    1. Set the rotary switch at desired A∼ position.
    2. Press the trigger to open transformer jaw and to clamp one conductor only, making sure that the jaw is firmly closed around the conductor.
    3. Read current value on LCD display.
    4. When only the figure “1” is displayed, it indicates overrange situation and the higher range has to be selected.

    Up

    How to measure resistance using ACM-1010 AC clamp meter and thermometer?

    1. Connect the red test lead to “V/Ω” jack and black test lead to the “COM” jack (The polarity of red lead is positive “+”).
    2. Set the rotary switch at desired ”Ω” range position.
    3. Connect test leads across the resistor to be measured and read LCD display.
    4. If the resistance being measured is connected to a circuit, turn off power and discharge all capacitors before applying test probes.

    Note:

    1. If the resistance being measured exceeds the maximum value of the range selected or the input is not connected, an overrange indication “1” will be displayed.
    2. When checking in-circuit resistance, be sure the circuit under test has all power removed and that all capacitors have been discharged fully.

    Up

    How to make audible continuity test using ACM-1010 AC clamp meter and thermometer?

    1. Connect red test lead to “V/Ω” jack, black test lead to “COM” jack.
    2. Set range switch to “” position.
    3. Connect test leads to two points of circuit to be tested. If continuity exists, built-in buzzer will sound.

    Up

    How to measure temperature using ACM-1010 AC clamp meter and thermometer?

    1. Set the rotary switch at 750°C position.
    2. Connect the red lead of “K” type thermocouple into the “V/Ω” jack and the black lead of “K” type thermocouple into the “COM” jack. The LCD display will show the current environment temperature.
    3. Contacting the object be measured with the thermocouple probe.
    4. Read temperature value on the LCD display.

    Up

    How to measure DC voltage using ACM-1010 AC clamp meter and thermometer?

    1. Connect the red test lead to the “V/Ω” jack and the black lead to the “COM” jack.
    2. Set rotary switch at desired 1000V position.
    3. Connect test leads across the source or load being measured.
    4. Read voltage value on the LCD display along with the polarity of the red lead connection.

    Up

    La pinza amperimtrica AKTAKOM ACM-1010 est diseada para la medicin sin contacto de la corriente elctrica alterna, as voltaje AC / DC, resistencia y entre otras mediciones la temperatura.

    Caractersticas:

    • Diametro maximo 1 1/2" (42 mm)
    • Prueba de continuidad audible
    • Seleccin manual de rangos
    • Botn de mantencin de datos
    • Pantalla con iluminacin de fondo

    Back to the section

    Please give us your feedback to help us improve our website

    * - required fields

    Site map|Privacy statement|Terms of Use & Store Policies|How to Buy|Shipping|Payment|© T&M Atlantic, Inc.,2010-2017