Español

ATK-2040 AC/DC TRMS Watt Clamp Meter

AKTAKOM ATK-2040 AC/DC TRMS Watt Clamp Meter
Click an image to enlarge
Brand:AKTAKOM
Warranty:1 year
User's Guide:Download
True RMS Bar graph indicator

Compact watt clamp meter is designed for the work in direct and one-phase alternating current networks

Retail price :$259.00

Depending on a destination shipping cost may vary.
Free shipping for orders over $450
on items weighting under 20 lbs
(certain restrictions apply!)

See shipping page for international rates
or contact sales@tmatlantic.com

Sold out

Subscribe

Compact AKTAKOM ATK-2040 watt clamp meter is designed for the work in direct and one-phase alternating current networks, it has built-in multimeter with voltage and frequency measurement function.

Features:

  • Accurate DC/AC digital clamp meter for current measurement.
  • One touch zero for DCA adjustment.
  • AC+DC 240K Watt Measurement
  • Large 3 3/4 digits LCD
  • Fast bargraph display (30 times/sec.) for transient observation.
  • Frequency measurements.
  • Max/Min and Data Hold functions.
  • Easy single rotary switch for any function selection.
  • Ideal for works in crowded switch box or cable areas.

DC Voltage (DCV)400 V
DCV Accuracy1.5%
DCV Resolution0.1 V
AC Voltage (ACV)400 V
ACV Accuracy2.0%
ACV Resolution0.1 V
DC Current (DCA)400 A
DCA Accuracy1.5%
DCA Resolution100 mA
AC Current (ACA)400 A
ACA Accuracy2.5%
ACA Resolution100 mA
Frequency100 kHz
Power240 kW
True RMS+
Data hold+
Min/Max measurement+
Relative measurement+
Jaw size0.9 in / 23 mm
Display3 3/4 LCD
Bar graph indicator+
Power supply2 x 1.5 V batteries
Dimensions7.2 x 2.5 x 1.4 in / 183 x 61.3 x 35.6 mm

Accuracy tables

DC Voltage

RangeResolutionAccuracyAbsolute errorValue-errorValue Learn an absolute error of your measurementValue+error
400 V 0.1 V (1.5%+3 digits) 6.2985 V V

AC Voltage

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
400 V 0.1 V (1.5%+3 digits) 6.2985 V V

DC Current

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
400 A 100 mA (1.5%+3 digits) 6.2985 A A

AC Current

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
400 A 100 mA (2.5%+4 digits) 10.3975 A A

Frequency

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
100 kHz 0.01 Hz (1.5%+3 digits) 1.50002985 kHz kHz

Active power

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
40 kW 0.01 kW (1.5%+3 digits) 0.62985 kW kW
240 kW 0.1 kW (1.5%+3 digits) 3.8985 kW kW

Specifications

AC+DC Watt

Range Resolution Accuracy Remarks
AC 40KW 10W 1.5%3dgts 1-250V, 1-400A, PF 0.6 -1, 50/60Hz, Vpeak < 360V
AC 240KW 100W 1.5%3dgts 1-600V, 1-400A, PF 0.6-1, 50/60Hz, Vpeak < 850V
AC 40KW 10W 2.5%3dgts 1-250V, 1-400A, PF 0.6 -1, 40-100Hz, Vpeak < 360V
AC 240KW 100W 2.5%3dgts 1-600V, 1-400A, PF 0.6-1, 40-100Hz, Vpeak < 850V
DC 40KW 10W 1.5%3dgts 1-250V, 1-400A
DC 240KW 100W 1.5%3dgts 1-600V, 1-400A

DC Current

Range Resolution Accuracy Overload Protection
400A 100mA 1.5%3dgts >DC 600A

AC Current (True RMS, Crest Factor < 4)



Accuracy Overload Protection
Range Resolution 50/60 Hz 40 - 100Hz
400A 100mA 1.5%3dgts 2.5%4dgts AC 600A

DC Voltage: (Input Impedance: 10M)

Range Resolution Accuracy Overload Protection
400V 0.1V 1.0%2dgts DC 800V

AC Voltage: (Input Impedance: 10M, True RMS, Crest Factor < 4)



Accuracy Overload Protection
Range Resolution 50/60 Hz 40 - 1KHz
600V 1V 1.5%2dgts 2.0%4dgts AC 800V

Frequency (Auto range):

Range (Hz) Resolution (Hz) Accuracy Sensitivity Overload Protection

1-100K 0.001 - 100 0.8%2dgts 10V AC 600V

Indoor Use

  • Battery Type: two 1.5V SUM-3
  • Display: 3 3/4 LCD with 40 seg. bargraph
  • Range Selection: manual
  • Overload Indication: OL
  • Power Consumption: 10 mA (approx.)
  • Auto-Power-Off: 15 minutes after power-on
  • Sampling Time:
    - 3 times/sec. (display)
    - 30 times/sec. (bargraph)
  • Operating Temperature: 14F to 122F / -10C to 50C
  • Operating Humidity: less than 85% relative
  • Altitude: up to 2000M
  • Storage Temperature: -4F to 140F / -20C to 60C
  • Storage Humidity: less than 75% relative
  • Dimension: 7.2in (L) x 2.5in (W) x 1.4in (H) / 183mm (L) x 61.3mm (W) x 35.6mm (H)
  • Weight: 6.7 oz / 190g (battery included)

Accessories:

  • Carrying bag
  • Users manual

DC Current Measurement

Note: Make sure that all the test leads are disconnected from the meter's terminals for current measurement.

  1. Set the rotary switch at 400A DC.
  2. Push the zero button to adjust the reading to zero.
  3. Press the trigger to open the jaw and fully enclose the conductor to be measured. No air gap is allowed between the two half jaws.

AC Current Measurement

Note: Make sure that all the test leads are disconnected from the meter's terminals for current measurement.

  1. Set the rotary switch at 400A AC
  2. Press the trigger to open the jaw and fully enclose the conductor to be measured. No air gap is allowed between the two half jaws.
  3. Read the measured value from the LCD display

DC voltage measurement

Note: Maximum input for DC V is 600, and for AC V is 600. Do not attempt to take any voltage measurement that exceeds the limits. Exceeding the limits could cause electrical shock and damage to the clamp meter.

  1. Set the rotary switch at V DC.
  2. Insert the test leads into the input jack.
  3. Connect the test prods of the test leads in PARALLEL to the circuit to be measured.
  4. Read the measured value from the LCD display.

AC voltage measurement

Note: Maximum input for DC V is 600, and for AC V is 600. Do not attempt to take any voltage measurement that exceeds the limits. Exceeding the limits could cause electrical shock and damage to the clamp meter.

  1. Set the rotary switch at V AC
  2. Insert the test leads into the input jack.
  3. Connect the test prods of the test leads in PARALLEL to the circuit to be measured.
  4. Read the measured value from the LCD display.

AC and DC Power and Watt Measurement

  1. Connect the test leads to the voltage source in parallel with the load.
  2. Clamp on one of the wire to the load.
  3. Select the range to Voltage AC or DC, and check the voltage reading.
  4. Select the range to Current AC or DC, and check the current reading.
  5. Select appropriate Watt range 40KW (0 - 250V, 0 - 400A) or 240KW (0 - 600V, 0 - 400A).
  6. Read the value shown on LCD in KW (AC+DC).

Frequency (Hz) Measurement

  1. Set the rotary switch at Hz.
  2. Insert the test leads into the input jack.
  3. Connect the test prods of the test leads in PARALLEL to the signal or circuit to be measured.
  4. Read the measured value from the LCD display.

Relative Reading Measurement

Note:

  • The ZERO button is disabled if Hz function is selected.
  • LCD displays relative numerical value without bargraph.

The zero button also can be used to make a relative measurement. Once the button is pushed, the current reading is set to zero and a zero symbol shall be displayed on LCD. All the subsequent measurement shall be displayed as a relative value with respect to the value being zeroed. Press the zero button again to return to normal mode. But this function is disabled if MAX/MIN function is enabled. Please watch for symbol displayed on LCD.

Frequently Asked Questions

  • How can I check MAX and MIN values when using AKTAKOM ATK-2040 clamp meter?
  • How to recover from Auto-Power-off when using AKTAKOM ATK-2040 clamp meter?

  • How can I check MAX and MIN values when using AKTAKOM ATK-2040 clamp meter?

    Press the MAX/MIN button to enable the maximum and minimum values to be recorded and updated during measurement. Push the button once, the maximum value shall be displayed and updated. The LCD display toggles between the MAX and MIN values. To exit MAX/MIN function, press and hold the MAX/MIN button for more than 2 seconds. If MAX/MIN button is pressed, the ZERO function will be disabled and the ZERO symbol will disappear from LCD.


    Up

    How to recover from Auto-Power-off when using AKTAKOM ATK-2040 clamp meter?

    • The meter will turn itself off 15 minutes after power-on (A symbol of APO is displayed in LCD). To turn it on again, user can either press any button or turn the rotary switch. Also pressing any button or turning the rotary switch will reset the 15 minute timer.
    • To disable the Auto-Power-Off function, hold the HOLD button while turning on power.

    Up


    Back to the section

    Please give us your feedback to help us improve our website

    * - required fields

    Choose your clamp meter!
    Site map|Privacy statement|Terms of Use & Store Policies|How to Buy|Shipping|Payment|© T&M Atlantic, Inc.,2010-2017