AM-1016 Network Multimeter for testing LAN cables & Phone lines

AKTAKOM AM-1016 Network Multimeter for testing LAN cables & Phone lines
Click an image to enlarge
Brand:AKTAKOM
Warranty:1 year
User's Guide:Download

Handheld multipurpose instrument with the functions of multimeter, network and telephone tester. Measurement of voltage (up to 1000V), current (up to 10A), resistance (up to 200MΩ). Using AM-1016 you can check T568A, T568B, 10Base-T, Token Ring.

Retail price :$49.00

Depending on a destination shipping cost may vary.
Free shipping for orders over $450
on items weighting under 20 lbs
(certain restrictions apply!)

See shipping page for international rates
or contact sales@tmatlantic.com

Almost sold out,4left

BuyAdd to cart

Handheld multipurpose instrument with the functions of multimeter, network and telephone tester.

Features:

  • 3 digits LCD display, 1999 counts
  • Telephone Line test (RJ11)
  • Network Line test (RJ-45)
  • Low battery indicator
  • Batteries test 1.5V, 6V, 9V
  • Overload protection
  • Sound beeper
  • Auto turn-off

DC Voltage (DCV)1000 V
DCV Accuracy(0.8%+2)
DCV Resolution0.1 mV
AC Voltage (ACV)700 V
ACV Accuracy(0.8%+3)
ACV Resolution0.1 mV
DC Current (DCA)10 A
DCA Accuracy(0.8%+3)
DCA Resolution0.1 μA
AC Current (ACA)10 A
ACA Accuracy(1.0%+3)
ACA Resolution0.1 μA
Resistance0.1 Ω...200 MΩ
Capacitance10 pF...5000 F
Diode test+
Continuity check+
Data hold+
Special featuresTelephone line test, Network line test, Battery test
DisplayLCD, 1999 counts
Power supply9 V battery
Dimensions7.3 x 3.3 x 1.7 in / 185 x 88 x 44 mm

Accuracy tables

DC Voltage

RangeResolutionAccuracyAbsolute errorValue-errorValue Learn an absolute error of your measurementValue+error
200 mV 0.1 mV (0.8%+2 digits) 1.7992 mV mV
2 V 1 mV (0.8%+2 digits) 0.017992 V V
20 V 10 mV (0.8%+2 digits) 0.17992 V V
200 V 100 mV (0.8%+2 digits) 1.7992 V V
1000 V 1 V (1.2%+3 digits) 14.988 V V

AC Voltage

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
200 mV 0.1 mV (1.2%+3 digits) 2.6988 mV mV
2 V 1 mV (0.8%+3 digits) 0.018992 V V
20 V 10 mV (0.8%+3 digits) 0.18992 V V
200 V 100 mV (0.8%+3 digits) 1.8992 V V
700 V 1 V (1.2%+5 digits) 13.388 V V

DC Current

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
200 A 0.1 A (0.8%+3 digits) 1.8992 A A
2 mA 1 A (0.8%+3 digits) 0.018992 mA mA
20 mA 10 A (0.8%+3 digits) 0.18992 mA mA
200 mA 100 A (1.5%+2 digits) 3.1985 mA mA
10 A 10 mA (2.0%+5 digits) 0.2498 A A

AC Current

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
200 A 0.1 A (1.0%+3 digits) 2.299 A A
2 mA 1 A (1.0%+3 digits) 0.02299 mA mA
20 mA 10 A (1.0%+3 digits) 0.2299 mA mA
200 mA 100 A (1.8%+3 digits) 3.8982 mA mA
10 A 10 mA (3.0%+5 digits) 0.3497 A A

Resistance

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
200 Ω 0.1 Ω (0.8%+3 digits) 1.8992 Ω Ω
2 kΩ 1 Ω (0.8%+2 digits) 0.017992 kΩ
20 kΩ 10 Ω (0.8%+2 digits) 0.17992 kΩ
200 kΩ 100 Ω (0.8%+2 digits) 1.7992 kΩ
2 MΩ 1 kΩ (0.8%+2 digits) 0.017992 MΩ
20 MΩ 10 kΩ (1.0%+2 digits) 0.2199 MΩ
200 MΩ 100 kΩ (5.0%+10 digits) 10.995 MΩ

Specifications

Function Range Resolution Accuracy
DC Voltage 200mV 0.1mV (0.8%reading+2digits)
2V 1mV
20V 10mV
200V 100mV
1000V 1V (1.2%reading+3digits)
AC Voltage (40 to 400Hz) 200mV 0.1mV (1.2%reading+3digits)
2V 1mV (0.8%reading+3digits)
20V 10mV
200V 100mV
700V 1V (1.2%reading+5digits)
All AC voltage ranges are specified from 5% of range to 100% of range
DC Current 200A 0.1A (0.8%reading+3digits)
2mA 1A
20mA 10A
200mA 100A (1.5%reading+2digits)
10A 10mA (2.0%reading+5digits)
(20A:30 sec max with reduced accuracy)
AC Current (40 to 400Hz) 200A 0.1A (1.0%reading+3digits)
2mA 1A (1.0%reading+3digits)
20mA 10A
200mA 100A (1.8%reading+3digits)
10A 10mA (3.0%reading+5digits)
All AC voltage ranges are specified from 5% of range to 100% of range
Overload Protection: F 200Ma/250V fuse for 200A to 200mA ranges

NOTE: Accuracy is stated at 18C to 28C (65F to 83F) and less than 75%RH. AC switch according to the calibration of sine wave.

Function Range Resolution Accuracy
Resistance 200Ω 0.1Ω (0.8%reading+3digits)
2kΩ (0.8%reading+2digits)
20kΩ 10Ω
200kΩ 100Ω
2MΩ 1kΩ
20MΩ 10kΩ (1.0%reading+2digits)
200MΩ 100kΩ (5.0%(reading-10digits)10digits)
Continuity buzzer: <70Ω

Battery test

Position 1.5V 6V 9V
Load 27Ω      100Ω

General specifications

Display: 1999 count backlit liquid crystal with bargraph.
Overrange indication: "OL" is displayed
Auto Power Off: 15 minutes (approximately) with disable feature
Polarity: automatic (no indication for positive); Minus (-) sign for negative
Measurement Rate: 2 times per second, nominal
Diode Test: test current of 0.9mA maximum, open circuit voltage 2.8V DC typical.
Continuity Check: audible signal will sound if the resistance is less than 70W (approx.)
Telephone Line test: RJ11
Network Cable test: RJ45 (T168A, T568B, 10Base-T and Token Ring)
Input Impedance: 10MΩ
AC Response: Rms
Enclosure: double molded
Shock (Drop Test): 2M Battery: One 9V (NEDA 1604 or 6F22) battery
Fuses: mA: F 200mA/250V 10A: no
Operating Temperature: 0C to 40C (32F to 104F)
Storage Temperature: -10C to 50C (14F to 140F)
Operating Humidity: Max 80% up to 31C (87F) decreasing linearly to 50% at 40C (104F)
Storage Humidity: <80%
Operating Altitude: 2000M maximum
Weight: 360g (includes holster)
Size: 185x85x44mm (includes holster)
Safety: Category III 1000V; Pollution Degree 2.

General accessories:

  • Test leads

  • Cable end cap

  • User manual

Controls of AM-1016 multimeter

Voltage measurement

  1. Connect the black test lead to the COM jack and the red test lead to the V/Ω jack.
  2. Set the rotary switch at the desired "V" range position and connect test leads across the source or load under measurement.
  3. Put down the "AC/DC" when measuring the voltage. Meter will be transformed between DC and AC range.
  4. If you need data hold when measuring, you can put on "HOLD", it will hold the reading; if you put the button again, data hold will not continue.
  5. When only the figure "1" is displayed, it indicates over range situation and the higher range has to be selected.

Current measurement

  1. Connect the black test lead to the COM jack and the red test lead to the A jack for a maximum of 200mA. For a maximum of 10A, move the red lead to the 10A jack.
  2. Set the rotary switch at desired "A" range position and connects test leads in series with the load under measurement.
  3. Put down the "AC/DC" when measuring the current. Meter will be transformed between DC and AC range.
  4. If you need data hold when measuring, you can put on "HOLD", it will hold the reading; if you put the button again, data hold will not continue.
  5. When only the Figure "1" is displayed, it indicates over range situation and the higher range has to be selected.

Testing Diode/Continuity

  1. Connect the black test lead to the COM jack and the red test lead to the V/Ω jack. (NOTE: The polarity of red lead connection is positive "+")
  2. Set the rotary switch at position and connect the red lead to the anode, the black lead to the cathode of the diode under testing. The meter will show the approx. Forward voltage drop of the diode. If the lead connection is reversed, only Figure "1" will be displayed. If continuity exists (i.e., resistance less than about 70Ω), built – in buzzer will sound.

Resistance measurement

  1. Connect the black test lead to the COM jack and the red test lead to the V/Ω jack. (NOTE: The polarity of red lead connection is positive "+")
  2. Set the rotary switch at desired Ω range position and connect test leads across the resistance under measurement. Read LCD display.

NOTE:

  1. For resistance above 1MΩ, the meter may take a few seconds to stabilize reading.
  2. When the input is not connected, i.e. at open circuit, the Figure "1" will be displayed for the overrange condition.
  3. When checking in – circuit resistance, be sure the circuit under test has all power removed and all capacitors are full discharged.
  4. At 200MΩ range display is 10 counts when test leads are shorted. These counts have to be subtracted from measuring results. For example, when measuring 100MΩ resistance, the reading will be 101.0 and the correct measuring result should be 101.0-1.0 = 100.0MΩ

Testing battery

  1. Connect the black test lead to the COM jack and the red test lead to the V/Ω jack.
  2. Set the rotary switch at the desired "BAT" range position and connect test leads across the battery.

Position1.5V6V9V
Load27Ω68Ω100Ω

Testing Telephone Line (RJ11)

  1. Connect the RJ11 test jack to one end of the telephone line to be tested.
  2. Connect the UAX (Telephone Unit Automatic Exchange) to the other end of the line.
  3. Push "TEST”' button to perform test.

Testing Network Cable (RJ45)

CAUTION! DO NOT use on the circuits as it may damage the tester.

The network tester is suitable for T168A, T568B, 10Base-T and Token Ring.

The Network Cable Tester will check a fault condition in the above descending order before detecting other fault conditions. The detection and indication of the presence of a fault is handled on a. "one-pertest" basis. Once a fault is corrected, it is recommended the cable be tested again for other faults.

OPEN There is no "OPEN" indication. A typical cable may have 2, 3, or 4 pairs. OPENS are displayed as an unlit symbol. The user will determine if a pair is present and continuous or OPEN by comparing the illuminated symbol to the expected number of pairs that should be good.

SHO. A short circuit condition exists (see Fig.1).

MIS. Indicates the improper assignment of individual wire pairs to pins for the wiring schemes tested (see Fig.2).

REV. Reverse wiring means the pin for one wire in a pair is connected to the opposite pin for the pair in the remote jack (see Fig.3).

SPL. Split pairs occur when the tip (positive conductor) and ring (negative conductor) of two twisted pairs are interchanged (see Fig.4).

  1. Connect the RJ45 test jack to one end of the cable to be tested.
  2. Connect the remote unit to the other end of the cable.
  3. Push TEST button to perform test. Example: The Cable Fault is a SHORT on Pair 1-2 and Pair 3-6, the LCD status will be as follows: Pair 1-2, Pair 3-6, Pair 4-5, Pair 7-8, SHIE and SHO will display at the same time.
  4. Push TEST button again, Pair 1-2, Pair 3-6 and SHO will display. Continue to Push TEST button, the next pairs will display.

Frequently Asked Questions

  • Does AKTAKOM AM-1016 multimeter have auto power off function?

  • Does AKTAKOM AM-1016 multimeter have auto power off function?

    No, AM-1016 multimeter doesn’t have this function.


    Up

    Digital Multimeter AKTAKOM AM-1016

    Instrumento multipropsito de mano con funsiones de multimetro y comprobador de cableado telefnico y de redes.

    Especificaciones:

    • Pantalla LCD de 3 digitos, 1999 cuentas
    • ConeccinRJ11 paraprueba telefnica
    • Coneccin RJ-45 para indicador de red digital
    • Indicador de bateria baja
    • Probador para baterias de 1.5V, 6V, 9V
    • Proteccin de sobrecarga
    • Zumbador
    • Apagado automtico

    Back to the section

    Please give us your feedback to help us improve our website

    * - required fields

    AKTAKOM APS-730xL series power supplies
    Site map|Privacy statement|Terms of Use & Store Policies|How to Buy|Shipping|Payment|© T&M Atlantic, Inc.,2010-2017