AKTAKOM AM-1060 digital multimeter provides multi function measurement: DCV, ACV, DCA, ACA, Resistance, Capacitance, Frequency, Temperature, Diode, Continuity beeper.

Features:

  • Meet IEC 1010 CATIII 1000V
  • Large LCD display with bar graph indication and frequency measurement path
  • Max./Min., Peak value, Relative, Data hold
  • Auto range with manual range selection
  • C/F thermometer
  • VAHz button, when execute the ACV, ACA function also can measure the frequency of signal
  • 4000 counts A/D, high resolution
  • Built-in fuse for both 10A, mA, uA current range
  • 10Mohm input impedance for voltage circuit
  • Full line optional adapters

DC Voltage (DCV)1000 V
DCV Accuracy(0.5%+2)
DCV Resolution0.1 mV
AC Voltage (ACV)1000 V
ACV Accuracy(1.0%+2)
ACV Resolution0.1 mV
DC Current (DCA)10 A
DCA Accuracy(1.0%+2)
DCA Resolution0.1 μA
AC Current (ACA)10 A
ACA Accuracy(1.0%+2)
ACA Resolution0.1 μA
Frequency1 Hz...40 MHz
Duty Cycle0.1%...99.9%
Resistance0.1 Ω...40 MΩ
Capacitance1 pF...40 mF
Temperature-20 C...+750 C
Temperature resolution1 C
Diode test+
Continuity check+
Autorange+
Data hold+
Min/Max measurement+
Peak hold+
Relative measurement+
DisplayLCD, 4000 counts
Bar graph indicator+
Power supply1.5 V x 2 batteries
Dimensions7.6 x 3.5 x 1.6 in / 194 x 89 x 40 mm

Accuracy tables

DC Voltage

RangeResolutionAccuracyAbsolute errorValue-errorValue Learn an absolute error of your measurementValue+error
400 mV 0.1 mV (0.5%+2 digits) 2.1995 mV mV
4 V 0.001 V (0.8%+1 digits) 0.032992 V V
40 V 0.01 V (0.8%+1 digits) 0.32992 V V
400 V 0.1 V (0.8%+1 digits) 3.2992 V V
1000 V 1 V (0.8%+1 digits) 8.992 V V

AC Voltage

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
400 mV 0.1 mV (1.0%+2 digits) 4.199 mV mV
4 V 0.001 V (1.0%+2 digits) 0.04199 V V
40 V 0.01 V (1.0%+2 digits) 0.4199 V V
400 V 0.1 V (1.0%+2 digits) 4.199 V V
1000 V 1 V (1.0%+2 digits) 11.99 V V

DC Current

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
400 A 0.1 A (1.5%+2 digits) 6.1985 A A
4000 A 1 A (1.5%+2 digits) 61.985 A A
40 mA 0.01 mA (1.0%+2 digits) 0.4199 mA mA
400 mA 0.1 mA (1.5%+2 digits) 6.1985 mA mA
10 A 0.01 A (1.0%+2 digits) 0.1199 A A

AC Current

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
400 A 0.1 A (1.5%+2 digits) 6.1985 A A
4000 A 1 A (1.5%+2 digits) 61.985 A A
40 mA 0.01 mA (1.0%+2 digits) 0.4199 mA mA
400 mA 0.1 mA (1.5%+2 digits) 6.1985 mA mA
10 A 0.01 A (1.0%+2 digits) 0.1199 A A

Frequency

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
4 kHz 0.001 kHz (0.5%+2 digits) 0.021995 kHz kHz
40 kHz 0.01 kHz (0.5%+2 digits) 0.21995 kHz kHz
400 kHz 0.1 kHz (0.5%+2 digits) 2.1995 kHz kHz
4 MHz 1 kHz (0.5%+2 digits) 0.021995 MHz MHz
40 MHz 10 kHz (0.5%+2 digits) 0.21995 MHz MHz

Resistance

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
400 Ω 0.1 Ω (1.0%+2 digits) 4.199 Ω Ω
4 kΩ 1 Ω (1.5%+2 digits) 0.061985 kΩ
40 kΩ 10 Ω (1.5%+2 digits) 0.61985 kΩ
400 kΩ 100 Ω (1.5%+2 digits) 6.1985 kΩ
4 MΩ 1 kΩ (1.5%+2 digits) 0.061985 MΩ
40 MΩ 10 kΩ (3.0%+5 digits) 1.2497 MΩ

Capacitance

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
4 nF 0.001 nF (3.0%+1 digits) 0.12097 nF nF
40 nF 0.01 nF (3.0%+1 digits) 1.2097 nF nF
400 nF 0.1 nF (3.0%+1 digits) 12.097 nF nF
4 F 0.001 F (3.0%+1 digits) 0.12097 F F
40 F 0.01 F (3.0%+1 digits) 1.2097 F F
400 F 0.1 F (3.0%+1 digits) 12.097 F F
4 mF 0.001 mF (4.0%+1 digits) 0.16096 mF mF
40 mF 0.01 mF (12.0%+1 digits) 4.8088 mF mF

Specifications

FunctionRangeResolutionAccuracy
DC Voltage
400mV0.1mV±(0.5%reading+2digits)
4V0.001V±(0.8%reading+1digits)
40V0.01V
400V0.1V
1000V1V
AC Voltage (50/60Hz) 400mV0.1mV±(1.0%reading+2digits)
4V0.001V
40V0.01V
400V0.1V
1000V1V
DC Current
400uA0.1uA±(1.5%reading+2digits)
4000uA1uA
40mA0.01mA±(1.0%reading+2digits)
400mA0.1mA±(1.5%reading+2digits)
10A0.01A±(1.0%reading+2digits)
AC Current (50/60Hz) 400uA0.1uA±(1.5%reading+2digits)
4000uA1uA
40mA0.01mA±(1.0%reading+2digits)
400mA0.1mA±(1.5%reading+2digits)
10A0.01A±(1.0%reading+2digits)
Resistance400Ω0.1Ω±(1.0%reading+2digits)
4kΩ±(1.5%reading+2digits)
40kΩ10Ω
400kΩ100Ω
4MΩ1kΩ
40MΩ10kΩ±(3.0%reading+5digits)
Continuity buzzer: <20Ω ; Max Voltage 500V (DC) / 250V (AC rms)
Capacitance 4nF
0.001nF

±(3.0%reading+1digits)
40nF
0.01nF
400nF
0.1nF
4uF 0.001uF
40uF
0.01uF
400uF 0.1uF
4mF 0.001mF ±(4.0%reading+1digits)
40mF 0.01mF ±(12.0%reading+1digits)
Frequency (response 1.5V...5V)
4kHz
0.001kHz ±(0.5%reading+2digits)
40kHz 0.01kHz
400kHz 0.1kHz
4MHz 1kHz
40MHz 10kHz
Temperature
(K-type)
-20°C...300°C1°C±(1.0%reading+2digits)
301°C...750°C1°C±(3.0%reading)

General specifications

Display: 2.6x2in/65x48mm large LCD (4000 counts) display with bar graph indication and frequency measurement path
Range selection: Auto range with manual range selecting
Data hold: To freeze the display reading on the LCD display
Memory recall: Records Maximum & Minimum readings with recall
Peak value: To measure the signal peak value (>1ms)
Relative measurement: To offset the measurement value
Polarity: Automatic Switching, "-" indicates negative polarity
Zero adjustment: Automatic
Sampling time: Approx. 0.5 to 1 second
Input impedance: 10Mohm.
Operating temperature: 0°C to 50°C (32°F to 122°F)
Operating humidity: Max. 80%RH.
Power supply: 1.5V battery x 2 PCs UM-4/AAA/Micro/R03 type
Power consumption: Approx. DC 1.7mA
Dimensions: 7.3x3.5x1.6in/185x88x40mm
Weight: 0.77lb/350g

General accessories:

  • Red and Black Test Lead
  • 0.5 Amp Spare Fuse
  • User Manual

Optional accessories:

  • Full line adapters: ACA/DCA current adapter, adapter, Tachometer adapter, Humidity adapter, Pressure adapter, Light adapter, EMF adapter, Sound level adapter, High voltage probe
  • Soft carrying case
  • Temperature probe

DMM basic measurement functions

As an example: oscilloscope diagnostic board AKTAKOM AEE-1017-V1 testing modes are given.


AC/DC Voltage (parallel connection to the circuit)

& Current (serial! connection to the break in circuit)

e.g.: sine output (3V/5kHz)


AC Voltage Line Frequency ("Hz" button)

e.g.: "FM" output (5kHz)

Resistance measurement

e.g.: 4.5 kOhm resistor

Capacitance

e.g.: SMD capacitor

Frequency (logic)

e.g.: Counter impulse frequency

Continuity (sound buzzer)

e.g.: between different "ground" points of the circuit

Temperature (K type probe)

e.g.: micro-chip surface temperature

Relative measurements (offset)

e.g.: leads resistance compensation

Diode test

e.g.: diode forward and backward Voltage drop


Frequently Asked Questions

  • How can I deactivate Auto Power Off function of AKTAKOM AM-1060 multimeter?
  • Does AKTAKOM AM-1060 multimeter have auto power off function?
  • How DMM is designed (disassembled view)
  • How to replace or install the batteries?

  • How can I deactivate Auto Power Off function of AKTAKOM AM-1060 multimeter?

    To deactivate Auto Power Off function press RS232 button.


    Up

    Does AKTAKOM AM-1060 multimeter have auto power off function?

    Yes, it does. There is Auto Power Off function in AM-1060: the device power automatically goes off if you do not use the device within 15 minutes. 30 seconds before the device powers off it will make 3 short sound signals and before powering off – one more long signal. To start the operation again press any button or use the rotary switch.


    Up

    How DMM is designed (disassembled view)

    Front panel covers LCD, button board, rotary function switch gear and main plated circuit board:

    *Rubber strip between the back and front chassis covers protects from water and dust.

    Protective fuses are mounted near the inputs and sound buzzer is placed behind the LCD.

    *There is also an extra fuse fixed at the buttom (for several models)
    Up

    How to replace or install the batteries?

    When the batteries become exhausted or drop below the operating voltage, “BAT” indicator will appear in the LCD display. In this case the battery should be replaced, however in-spec. measurements may still be made for several hours after "Low battery indicator" appears before the instrument become inaccurate.

    WARNING! To avoid electric shock, disconnect the test leads from any source of voltage before removing the battery cover.

    "DC 9V" type 006 P (e.g. AMM-1061)

    1. Open the battery cover by loosing the screws with the cross-point screwdriver

    2. Carefully disconnect the old battery

    3. Connect the new battery of the proper type to the power leads

    4. Close the battery cover and reinstate the cover

    "DC 1.5V" type AAA (e.g. AMM-1060)

    1. Open the battery cover by loosing the screws with the cross-point screwdriver

    2. Carefully pull out the buttery carrier and take off the old batteries

    3. Plug the new batteries of the proper type in the holder and put it back

    4.Close the battery cover and reinstate the cover

    After completion make sure you don’t have any spare parts

    If you do find spare parts, you must start all over


    Up

    AKTAKOM AM-1060 ofrecemultiples funciones de medicin como DCV, ACV, DCA, ACA, resistencia, capacitancia, frecuencia, temperatura, testeo de diodos y zumbador de continuidad.

    Caractersticas:

    • Cumple con la norma IEC 1010 CAT III 1000V.
    • Monitor digital LCD con indicador grfico de barras.
    • Deteccin de picos con Mximo y mnimo, alternos y retencin de datos.
    • Auto rango con seleccin manual de los mismos.
    • Termometro C/F
    • Botn VAHz, cuando se ejecuta la funcin de ACV, ACA y tambin puede medir la frecuencia de la seal.
    • Alta resolucin con 4000 cuentas A/D.
    • Fusible incorporado para los rangos de corriente 10 A, mA, uA.
    • Impedancia de entrada de 10 M ohm para el circuito de tensin.
    • Lnea completa de adaptadores opcionales.

    Back to the section

    Please give us your feedback to help us improve our website

    * - required fields

    Choose your clamp meter!
    Site map|Privacy statement|Terms of Use & Store Policies|How to Buy|Shipping|Payment|© T&M Atlantic, Inc.,2010-2017