Español

AMM-1009 General purpose 20 A Digital Multimeter with Logic Tester

AKTAKOM AMM-1009 General purpose 20 A Digital Multimeter with Logic Tester
Click an image to enlarge
Brand:AKTAKOM
Warranty:1 year
User's Guide:Download

Retail price :$59.00

Depending on a destination shipping cost may vary.
Free shipping for orders over $450
on items weighting under 20 lbs
(certain restrictions apply!)

See shipping page for international rates
or contact sales@tmatlantic.com

In stock now

BuyAdd to cart

AKTAKOM AMM-1009is a high performance Digital Multimeter with double molded plastic housing and over sized high contrast 4000 counts LCD display. Itconforms toEN61010-1, Double insulation, CAT III 1000V / CAT IV 600V safety standards and full ranges protection.

Features

1. 4000 counts digital display
2. Data hold function
3. Auto power off and low battery indication
4. 1000V over-voltage protection
5. Measurement Rate: 2 times per second, nominal

DC Voltage (DCV)1000 V
DCV Accuracy(0.5%+1)
DCV Resolution0.1 mV
AC Voltage (ACV)750 V
ACV Accuracy(1.0%+4)
ACV Resolution0.1 mV
DC Current (DCA)20 A
DCA Accuracy(1.0%+1)
DCA Resolution10 A
AC Current (ACA)20 A
ACA Accuracy(1,5%+4)
ACA Resolution10 A
Frequency1 Hz...4000 kHz
Resistance0.1 Ω...200 MΩ
Capacitance1 pF...40 F
Diode test+
Continuity check+
Data hold+
Special featuresLogic test
DisplayLCD, 4000 counts
Power supply9 V battery
Dimensions7.2 x 3.2 x 2.2 in / 182 x 82 x 55 mm

Accuracy tables

DC Voltage

RangeResolutionAccuracyAbsolute errorValue-errorValue Learn an absolute error of your measurementValue+error
400 mV 0.1 mV (0.5%+1 digits) 2.0995 mV mV
4 V 1 mV (0.5%+1 digits) 0.020995 V V
40 V 10 mV (0.5%+1 digits) 0.20995 V V
400 V 100 mV (0.5%+1 digits) 2.0995 V V
1000 V 1 V (0.5%+1 digits) 5.995 V V

AC Voltage

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
400 mV 0.1 mV (1.0%+4 digits) 4.399 mV mV
4 V 1 mV (1.0%+4 digits) 0.04399 V V
40 V 10 mV (1.0%+4 digits) 0.4399 V V
400 V 100 mV (1.0%+4 digits) 4.399 V V
750 V 1 V (1.5%+4 digits) 15.235 V V

DC Current

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
40 mA 10 A (1.0%+1 digits) 0.4099 mA mA
400 mA 100 A (1.0%+1 digits) 4.099 mA mA
20 A 10 mA (3.0%+1 digits) 0.6097 A A

AC Current

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
40 mA 10 A (1.5%+4 digits) 0.63985 mA mA
400 mA 100 A (1.5%+4 digits) 6.3985 mA mA
20 A 10 mA (3.5%+4 digits) 0.73965 A A

Resistance

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
400 Ω 0.1 Ω (0.8%+4 digits) 3.5992 Ω Ω
4 kΩ 1 Ω (0.8%+2 digits) 0.033992 kΩ
40 kΩ 10 Ω (0.8%+2 digits) 0.33992 kΩ
400 kΩ 100 Ω (0.8%+2 digits) 3.3992 kΩ
4 MΩ 1 kΩ (0.8%+2 digits) 0.033992 MΩ
40 MΩ 10 kΩ (3.0%+4 digits) 1.2397 MΩ
400 MΩ 100 kΩ (10.0%+10 digits) 40.99 MΩ

Capacitance

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
4 nF 1 pF (5.0%+10 digits) 0.20995 nF nF
40 nF 10 pF (5.0%+10 digits) 2.0995 nF nF
400 nF 0.1 nF (5.0%+10 digits) 20.995 nF nF
4 F 1 nF (5.0%+10 digits) 0.20995 F F
40 F 10 nF (5.0%+10 digits) 2.0995 F F

Specifications

Function Range Resolution Accuracy
DC Voltage 400mV 0.1mV (0.5%reading+1digits)
4V 0.001V
40V 0.01V
400V 0.1V
1000V 1V
AC Voltage (50 to 500Hz) 400mV 0.1mV (1.0%reading+4digits)
4V 0.001V
40V 0.01V
400V 0.1V
750V 1V (1.5%reading+4digits)
DC Current
40mA 0.01mA (1.0%reading+1digits)
400mA 0.1mA
20A 0.01A (3.0%reading+1digits)
AC Current (50 to 500Hz) 40mA 0.01mA (1.5%reading+4digits)
400mA 0.1mA (3.5%reading+4digits)
20A 0.01A (3.0%reading+10digits)
Resistance 400Ω 0.1Ω (0.8%reading+4digits)
4kΩ

(0.8%reading+2digits)

40kΩ 10Ω
400kΩ 100Ω
4MΩ 1kΩ
40MΩ 10kΩ (3.0%reading+4digits)
400MΩ 100kΩ (3.0%(reading-20digits)+10digits)
Continuity buzzer: <100Ω ; Max Voltage 500V (AC rms / DC)
Capacitance 4nF
0.001nF
(5.0%reading+10digits)
40nF
0.01nF
400nF
0.1nF
4uF 0.001uF
40uF
0.01uF
Frequency (response 200mV...2V)
4kHz
0.001kHz (0.1%reading+1digits)
40kHz 0.01kHz
400kHz 0.1kHz
4000kHz 1kHz

General specifications

Display: 3999counts, large symbols.
Overvoltage category: CAT II 1000V.
Insulation: Class2, Double insulation.
Polarity: Automatic, (-) negative polarity indication.
Overrange: "OL" mark indication.
TTL Test: Hi/Low (20MHz, 500V)
Low battery indication: The "BAT" is displayed when the battery voltage drops below the operating level.
Measurement rate: 2.5 times per second, nominal.
Operating environment: 0C to 50C (32F to 122F) at < 70% relative humidity.
Storage temperature: -20C to 60C (-4F to 140F) at < 80% relative humidity.
Power: One 9V battery, NEDA 1604, IEC 6F22.
Dimensions: 7.23.22.2in/1828255mm
Weight: Approx.: 375g

General accessories:

1. Test leads

2. 9V battery (design may vary)

3. Gift box with carrying case

Voltage measurement

  1. Connect the black test lead to COM jack and the red test lead to VΩ jack
  2. Set the Function/Range switch to the desired voltage type (AC or DC) and range. If magnitude of voltage is not known, set switch to the highest range and reduce until a satisfactory reading is obtained
  3. Connect the test leads to the device or circuit being measured
  4. For DC, a (-) sign is displayed for negative polarity; positive polarity is implied

Current measurement

  1. Set the Function/Range switch to the desired current type (AC or DC) and range
  2. For current measurements less than 400mA, connect the red test leads to the mA jack and the black test lead to COM jack
  3. For current measurements over 400mA or greater, connect the red test leads to the 10A jack and the black test lead to the COM jack
  4. Remove power from the circuit under test and open the normal circuit path where the measurement is to be taken. Connect the meter in series with the circuit
  5. Use caution when measuring 10 amps on 10A range for 30s, please waiting for 10 minutes for next measurement of 10 amps for safety reason.

Resistance and continuity measurement

WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements. Remove the batteries and unplug the line cords.

  1. Set the Function/Range switch to the desired resistance range or continuity position
  2. Remove power from the equipment under test
  3. Connect the black test lead to COM jack and the red test lead to VΩ jack.
  4. Touch the probes to the test points. In ohms, the value indicated in the display is the measured value of resistance. In continuity test, the beeper sounds continuously, if the resistance is less than 100Ω.
  5. When using 400MΩ Range; The 400MΩ Range has a fixed 20±2-count offset in the reading. When the test leads are shorted together in this range, the meter will display 102.0. The residual reading must be subtracted from the reading obtained in step 4 when this range is used. For example, when measuring 100MΩ on the 400mΩ range, the display will read 102.0, from which the 20 residual is subtracted to obtain the actual resistance of 100.0MΩ.

WARNING: The accuracy of the functions might be slightly affected, when exposed to a radiated electromagnetic field environment, eg, radio, telephone or similar.

Diode test

  1. Connect the black test lead to COM jack and the red test lead to VΩ jack.
  2. Set the function switch to the position.
  3. Turn off power to the circuit under test.
  4. Touch probes to the diode. A forward-voltage drop is about 0.6V (typical for a silicon diode).
  5. Reverse the probes. If the diode is good, "OL" is displayed. If the diode is shorted, ".000" or another number is displayed.
  6. If the diode is open, "OL" is displayed in both directions.
  7. If the junction is measured in a circuit and a low reading is obtained with both lead connections, the junction may be shunted by a resistance of less than 1kΩ. In this case the diode must be disconnected from the circuit for accurate testing.

Frequency measurement

WARNING: To avoid electric shock, discharge the capacitor under test before measuring.

  1. Set the Function/Range switch to the "Hz" position.
  2. Connect the red test lead to thea VΩ jack. and the black test lead to the COM jack.
  3. Connect the test leads to the point of measur ement and read the frequency from the display.

Capacitance measurement

  1. Set the Function/Range switch to the desired F range.
  2. Never apply an external voltage to the Cx sockets. Damage to the meter may result.
  3. Read the capacitance directly from the display.

Logic measurement

  1. Set the function/range switch to the logic position.
  2. Connect the red test lead to the VΩ jack and the black test lead to the COM jack.
  3. Connect the red test lead to the test point and the black lead to the common buss of the logic circuit.
  4. A "↑" on the display indicates TTL logic high and a "↓" indicates a TTL logic low. Both indicators are on when the point of measurement is toggling high and low.

Frequently Asked Questions

  • Does AKTAKOM AMM-1009 multimeter have auto power off function?
  • How can I deactivate Auto Power Off function of AKTAKOM AMM-1009 multimeter?

  • Does AKTAKOM AMM-1009 multimeter have auto power off function?

    Yes, it does. There is Auto Power Off function in AMM-1009: the device power automatically goes off if you do not use the device within 15 minutes. Press any button to start the operation again.


    Up

    How can I deactivate Auto Power Off function of AKTAKOM AMM-1009 multimeter?

    Auto Power Off function can’t be disabled in AMM-1009 multimeter.


    Up

    Digital Multimeter AKTAKOM AMM-1009

    AKTAKOM AMM-1009 es un dispositivo de alto rendimiento con doble carcasa de plstico moldeado y un monitor LCD de alto contraste, sobredimensionado de 4000 cuentas. Cumple con las normas de seguridad estndar y de proteccin en todos los rangos en conformidad con la EN61010-1, doble aislamiento, CAT III 1000V / CAT IV 600V.

    Caractersticas:

    • Pantalla digital de 4000 cuentas.
    • Retencin de datos.
    • Apagado automtico e indicador de batera baja.
    • Proteccin de 1000V de sobretensin.
    • Velocidad de medicin: 2 veces por segundo, nominal.