AKTAKOM AMM-1008 Digital Multimeter offers high accuracy and all the measurement functions in a compact size. It has double molded plastic housing and oversized high contrast 2000 counts LCD display with backlight.

Features

  • LCD 3 1/2 digit (2000 counts), the backlight
  • Double-walled housing
  • Hold function for reading
  • Full overload protection on all ranges
  • Battery Indicator
  • Convenient stand (with suspension)
  • Protection category: CAT III 600V; CAT II 1000V

DC Voltage (DCV)1000 V
DCV Accuracy(0.5%+2)
DCV Resolution0.1 mV
AC Voltage (ACV)700 V
ACV Accuracy(1.0%+3)
ACV Resolution1 mV
DC Current (DCA)20 A
DCA Accuracy(1.0%+3)
DCA Resolution1 A
AC Current (ACA)20 A
ACA Accuracy(1.2%+3)
ACA Resolution1 A
Frequency0.01 Hz...20 kHz
Resistance0.1 Ω...20 MΩ
Capacitance1 pF...200 F
Temperature-20 C...+760 C / -4 F...+1400 F
Temperature resolution1 C / 1 F
Diode test+
Continuity check+
Data hold+
DisplayLCD, 2000 counts
Power supply9 V battery
Dimensions7.7 x 3.6 x 1.5 in / 195 x 92 x 38 mm

Accuracy tables

DC Voltage

RangeResolutionAccuracyAbsolute errorValue-errorValue Learn an absolute error of your measurementValue+error
200 mV 0.1 mV (0.5%+2 digits) 1.1995 mV mV
2 V 1 mV (0.5%+2 digits) 0.011995 V V
20 V 10 mV (0.5%+2 digits) 0.11995 V V
200 V 100 mV (0.5%+2 digits) 1.1995 V V
1000 V 1 V (0.8%+2 digits) 9.992 V V

AC Voltage

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
2 V 1 mV (1.0%+3 digits) 0.02299 V V
20 V 10 mV (1.0%+3 digits) 0.2299 V V
200 V 100 mV (1.0%+3 digits) 2.299 V V
700 V 1 V (1.2%+5 digits) 13.388 V V

DC Current

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
2 mA 1 A (1.0%+3 digits) 0.02299 mA mA
20 mA 10 A (1.5%+3 digits) 0.32985 mA mA
200 mA 100 A (1.5%+3 digits) 3.2985 mA mA
20 A 10 mA (2.5%+10 digits) 0.59975 A A

AC Current

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
2 mA 1 A (1.2%+3 digits) 0.026988 mA mA
20 mA 10 A (2.0%+3 digits) 0.4298 mA mA
200 mA 100 A (2.0%+3 digits) 4.298 mA mA
20 A 10 mA (3.0%+10 digits) 0.6997 A A

Resistance

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
200 Ω 0.1 Ω (1.0%+4 digits) 2.399 Ω Ω
2 kΩ 1 Ω (1.0%+2 digits) 0.02199 kΩ
20 kΩ 10 Ω (1.2%+2 digits) 0.25988 kΩ
200 kΩ 100 Ω (1.2%+2 digits) 2.5988 kΩ
2 kΩ 1 kΩ (1.2%+2 digits) 2.012 kΩ
20 MΩ 10 kΩ (2.0%+5 digits) 0.4498 MΩ

Capacitance

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
2 nF 1 pF (4.0%+10 digits) 0.08996 nF nF
20 nF 10 pF (4.0%+3 digits) 0.8296 nF nF
200 nF 0.1 nF (4.0%+3 digits) 8.296 nF nF
2 F 1 nF (4.0%+3 digits) 0.08296 F F
200 F 0.1 F (4.0%+5 digits) 8.496 F F

Specifications

Function Range Resolution Accuracy
DC Voltage 200mV 0.1mV (0.5% + 2 digits)
2V 0.001V
20V 0.01V
200V 0.1V
1000V 1V (0.8% + 2 digits)
AC Voltage (50 to 400Hz) 200mV 0.1mV (1.0% + 3 digits)
2V 0.001V
20V 0.01V
200V 0.1V
1000V 1V (1.2% + 5 digits)
DC Current
2mA 0.001mA (1.0% + 3 digits)
20mA 0.01mA (1.5% + 3 digits)
200mA 0.1mA
20A 0.01A (2.5% + 10 digits)
AC Current (40 to 400Hz) 2mA 0.001mA (1.2% + 3 digits)
200mA 0.1mA (2.0% + 3 digits)
20A 0.01A (3.0% + 10 digits)
Resistance 200Ω 0.1Ω (1,0% + 4 digits)
2kΩ (1,0% + 2 digits)
20kΩ 10Ω (1,2% + 2 digits)
200kΩ 100Ω
2MΩ 1kΩ
20MΩ 10kΩ (2.0% + 5 digits)
Continuity buzzer: <50Ω ; Max Voltage 250V (AC rms / DC)
Capacitance 2nF
0.001nF
(4.0% + 10 digits)
20nF
0.01nF
(4.0% + 3 digits)
200nF
0.1nF
2uF 0.001uF
200uF
0.1uF
(7.0% + 50 digits)
Frequency (response 200mV ... 10V)
20kHz
0.01kHz (1.5% + 5 digits)
Temperature (K-type)
-20C ... 760C 1C/F
(3,0% + 3 digits)
-4F ... 1400F

General specifications

Display: 2000 counts, large symbols.
Overvoltage category: CAT II 1000V.
Insulation: Class2, Double insulation.
Polarity: Automatic, (-) negative polarity indication.
Overrange: OL mark indication.
Low battery indication: The BAT is displayed when the battery voltage drops below the operating level.
Measurement rate: 2 times per second, nominal.
Operating environment: 0C to 50C (32F to 122F) at < 70% relative humidity.
Storage temperature: -20C to 60C (-4F to 140F) at < 80% relative humidity.
Power: One 9V battery, NEDA 1604, IEC 6F22.
Dimensions (HЧW?H): 7.7x3.6x1.5in / 195x92x38mm
Weight: Approx.: 13.4oz / 380g 

General accessories:

  • Red and Black Test Leads
  • Type K temperature probe

  • 9V battery
  • User Manual

DC voltage measurement

CAUTION: Do not measure DC voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter.

  1. Set the function switch to the V DC position ("mV" will appear in the display)
  2. Insert the black test lead banana plug into the negative (COM) jack and the red test lead banana plug into the positive (V) jack
  3. Be sure to observe the correct polarity (red lead to positive, black lead to negative)
  4. Read the voltage in the display. The display will indicate the proper decimal point and value. If the polarity is reversed, the display will show (-) minus before the value.

AC voltage measurement

WARNING: Risk of Electrocution. The probe tips may not be long enough to contact the live parts inside some 240V outlets for appliances because the contacts are recessed deep in the outlets. As a result, the reading may show 0 Volts when the outlet actually has voltage on it. Make sure the probe tips are touching the metal contacts inside the outlet before assuming that no voltage is present.
CAUTION: Do not measure AC voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter.

  1. Set the function switch to the V AC position.
  2. Insert the black test lead banana plug into the negative (COM) jack and the red test lead banana plug into the positive (V) jack.
  3. Touch the test probe tips to the circuit under test.
  4. Read the voltage in the display. The display will indicate the proper decimal point, value and symbol (AC, V, etc.).

DC current measurement

CAUTION: Do not make current measurements on the 20A scale for longer than 30 seconds. Exceeding 30 seconds may cause damage to the meter and/or the test leads.

  1. Insert the black test lead banana plug into the negative (COM) jack
  2. For current measurements up to 200mA DC, set the function switch to the mA range and insert the red test lead banana plug into the (mA) jack
  3. For current measurements up to 20A DC, set the function switch to the A position and insert the red test lead banana plug into the 20A jack
  4. Remove power from the circuit under test, then open up the circuit at the point where you wish to measure current
  5. Touch the black test probe tip to the negative side of the circuit. Touch the red test probe tip to the positive side of the circuit
  6. Apply power to the circuit
  7. Read the current in the display. The display will indicate the proper decimal point, value.

AC current measurement

WARNING: To avoid electric shock, do not measure AC current on any circuit whose voltage exceeds 250V AC.
CAUTION: Do not make current measurements on the 20A scale for longer than 30 seconds. Exceeding 30 seconds may cause damage to the meter and/or the test leads.

  1. Insert the black test lead banana plug into the negative (COM) jack
  2. For current measurements up to 200mA AC, set the function switch to the mA range and insert the red test lead banana plug into the (mA) jack
  3. For current measurements up to 20A AC, set the function switch to the A position and insert the red test lead banana plug into the 20A jack
  4. Remove power from the circuit under test, then open up the circuit at the point where you wish to measure current
  5. Touch the black test probe tip to the negative side of the circuit. And touch the red test probe tip to the positive side of the circuit
  6. Apply power to the circuit
  7. Read the current in the display. The display will indicate the proper decimal point, value.

Resistance measurement

WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements. Remove the batteries and unplug the line cords.

  1. Set the function switch to the Ω position
  2. Insert the black test lead banana plug into the negative (COM) jack and the red test lead banana plug into the positive Ω jack
  3. Touch the test probe tips across the circuit or part under test. It Is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading
  4. Read the resistance in the display. The display will indicate the proper decimal point, value.

Continuity check

WARNING: To avoid electric shock, never measure continuity on circuits or wires that have voltage on them.

  1. Set the function switch to the position.
  2. Insert the black lead banana plug into the negative (-) jack (COM) and the red test lead banana plug into the positive (+) jack (Ω).
  3. Touch the test probe tips to the circuit or wire you wish to check.
  4. If the resistance is less than approximately 50Ω, the audible signal will sound. The display will also show the actual resistance.

Diode test

WARNING: To avoid electric shock, do not test any diode that has voltage on it.

  1. Set the function switch to position.
  2. Insert the black test lead banana plug into the negative (-) jack (COM) and the red test lead banana plug into the positive (+) jack (Ω).
  3. Touch the test probe tips to the diode or semiconductor junction you wish to test. Note the meter reading
  4. Reverse the probe polarity by switching probe position. Note this reading.
  5. The diode or junction can be evaluated as follows:
    A. If one reading shows a value and the other reading shows "1", the diode is good.
    B. If both readings show "1", the device is open.
    C. If both readings are very small or 0, the device is shorted.

    NOTE: The value indicated in the display during the diode check is the forward voltage.

Frequency measurement

  1. Set the function switch to the 20kHz position.
  2. Insert the black test lead banana plug into the negative (-) jack (COM) and the red test lead banana plug into the positive (+) jack (F).
  3. Touch the test probe tips to the circuit under test.
  4. Read the frequency in the display. The digital reading will indicate the proper decimal point, value.

Capacitance measurement

WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements. Remove the batteries and unplug the line cords.

  1. Set the function switch to the CAP position.
  2. Insert the black test lead banana plug into the negative (-) jack (COM) and the red test lead banana plug into the positive (+) jack (CAP).
  3. Touch the test leads to the capacitor to be tested. The display will indicate the proper decimal point, value

Temperature measurement

WARNING: To avoid electric shock, disconnect both test probes from any source of voltage before making a temperature measurement.

  1. If you wish to measure temperature in °F, set the function switch to the F range. If you wish to measure temperature in C, set the function switch to the C range.
  2. Insert the Temperature Probe into the negative (-) jack (COM) and the positive (+) jack (Temperature), making sure to observe the
  3. Touch the Temperature Probe head to the part whose temperature you wish to measure. Keep the probe touching the part under test until the reading stabilizes (about 30 seconds).
  4. Read the temperature in the display. The digital reading will indicate the proper decimal point and value.

WARNING: To avoid electric shock, be sure the thermocouple has been removed before changing to another measurement function.

Frequently Asked Questions

  • Does AKTAKOM AMM-1008 multimeter have auto power off function?
  • How can I deactivate Auto Power Off function of AKTAKOM AMM-1008 multimeter?

  • Does AKTAKOM AMM-1008 multimeter have auto power off function?

    Yes, it does. There is Auto Power Off function in AMM-1008: the device power automatically goes off if you do not use the device within 15 minutes. Press any button to start the operation again.


    Up

    How can I deactivate Auto Power Off function of AKTAKOM AMM-1008 multimeter?

    Auto Power Off function can’t be disabled in AMM-1008 multimeter.


    Up

    AKTAKOM AMM-1008 ofrece una alta precisin y todas las funciones de medicin que usted pueda necesitar siendo este un instrumento de mano. Cuenta con doble carcasa de plstico moldeado de gran tamao y alto contraste en el monitor LCD de 2000 cuentas.

    Caractersticas:

    • Pantalla digital con luz de fondo de 2000 cuentas.
    • Retencin de datos.
    • Proteccin de sobrecarga en todos los rangos.
    • Seal simblica de BAT.

    Back to the section

    Please give us your feedback to help us improve our website

    * - required fields

    Site map|Privacy statement|Terms of Use & Store Policies|How to Buy|Shipping|Payment|© T&M Atlantic, Inc.,2010-2017