Español

AMM-1063 Smart Pen-type Digital Multimeter for IT

Absolute error of my measurement

"Absolute measurement error" service allows you to estimate the measurement accuracy considering uncertainty (error) in the absolute value. It’s important if you take measurements at the range edge when the error value contributes to the value displayed on the device screen.

To get the value range it’d be enough to enter the estimate of the value under measurement into Value input field and to see the range of possible values taking all of the standardized errors into consideration.

Note: a point is used as a separator of the integer and fractional part.

Software delivery

General accessories:

1. Manual

2. Probe tip (clamshell)

3. Crocodile clip

4. Fuse

5. Button batteries

AKTAKOM AMM-1063 Smart Pen-type Digital Multimeter for IT
Click an image to enlarge
Brand: AKTAKOM
Warranty: 1 year
User's Guide: Download

 

Retail price : $70.00

Estimated shipping cost $12 (Continental US only!)
Depending on a destination shipping cost may vary.
Free shipping for orders over $450
on items weighting under 20 lbs
(certain restrictions apply!)

See shipping page for international rates
or contact sales@tmatlantic.com

In stock now

Buy Add to cart

AKTAKOM AMM-1063 is ideal for electrical troubleshooting, can be used for components check (resistance, capacitance, diode and continuity) and circuit fault detection.  

All inputs are protected to EN 610101-1 CATIII 600V.

Features:

  • Automatic DCV or ACV selection, Capacitance, Resistance, Continuity and diode selection
  • 6000 counts LCD display
  • Auto/manual ranging
  • Data Hold/MAX/MIN recording mode
  • Auto Power Off
  • Wide capacitance range
  • Diode Check & Continuity Test

Attention. Discounts for various special offers are not cumulative.

DC Voltage (DCV)600 V
DCV Accuracy±(1.2%+5)
DCV Resolution0.1 mV
AC Voltage (ACV)600 V
ACV Accuracy±(1.5%+3)
ACV Resolution0.1 mV
DC Current (DCA)600 mA
DCA Accuracy±(1.5%+5)
DCA Resolution10 µA
AC Current (ACA)600 mA
ACA Accuracy±(2.0%+5)
ACA Resolution10 µA
Resistance0.1 Ω...60 MΩ
Capacitance1 pF...10 mF
Diode test+
Continuity check+
Autorange+
Data hold+
Min/Max measurement+
DisplayLCD, 6000 counts
Power supplyButton battery
Dimensions9.1 x 1.4 x 0.8 in / 230 x 35 x 20 mm

Accuracy tables

DC Voltage

RangeResolutionAccuracyAbsolute errorValue-errorValue Learn an absolute error of your measurementValue+error
600 mV 0.1 mV ±(1.2%+5 digits) ±7.6988 mV mV
6 V 1 mV ±(1.5%+5 digits) ±0.094985 V V
60 V 10 mV ±(1.5%+5 digits) ±0.94985 V V
600 V 100 mV ±(1.5%+5 digits) ±9.4985 V V

AC Voltage

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
600 mV 0.1 mV ±(1.5%+30 digits) ±11.9985 mV mV
6 V 1 mV ±(1.5%+3 digits) ±0.092985 V V
60 V 10 mV ±(2.0%+3 digits) ±1.2298 V V
600 V 100 mV ±(2.0%+3 digits) ±12.298 V V

DC Current

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
60 mA 10 µA ±(1.5%+5 digits) ±0.94985 mA mA
600 mA 100 µA ±(1.5%+5 digits) ±9.4985 mA mA

AC Current

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
60 mA 10 µA ±(2.0%+5 digits) ±1.2498 mA mA
600 mA 100 µA ±(2.0%+5 digits) ±12.498 mA mA

Resistance

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
600 Ω 0.1 Ω ±(1.2%+4 digits) ±7.5988 Ω Ω
6 kΩ 1 Ω ±(1.0%+2 digits) ±0.06199 kΩ
60 kΩ 10 Ω ±(2.0%+2 digits) ±1.2198 kΩ
600 kΩ 100 Ω ±(2.0%+2 digits) ±12.198 kΩ
6 MΩ 1 kΩ ±(2.0%+2 digits) ±0.12198 MΩ
60 MΩ 10 kΩ ±(2.5%+3 digits) ±1.52975 MΩ

Capacitance

RangeResolutionAccuracyAbsolute errorValue-errorValueValue+error
6 nF 1 pF ±(5.0%+50 digits) ±0.34995 nF nF
60 nF 10 pF ±(5.0%+7 digits) ±3.0695 nF nF
600 nF 0.1 nF ±(3.0%+5 digits) ±18.497 nF nF
6 µF 1 nF ±(3.0%+5 digits) ±0.18497 µF µF
60 µF 10 nF ±(3.0%+5 digits) ±1.8497 µF µF
600 µF 0.1 µF ±(5.0%+5 digits) ±30.495 µF µF
6 mF 1 µF ±(5.0%+5 digits) ±0.30495 mF mF
10 mF 10 µF ±(10.0%+5 digits) ±1.049 mF mF

Features

  • Manual range / auto scan modes
  • Data hold
  • MIN/MAX hold

Specifications:

Function Ranges Basic Accuracy
Voltage DC 600.0mV, 6.000V, 60.00V, 600.0V ±(1.2%+5d)
Voltage AC (50...400Hz)600.0mV (50/60Hz), 6.000V, 60.00V, 600.0V ±(1.5%+3d)
Current DC 60.00mA, 600.0mA ±(1.5%+5d)
Current AC (50...400Hz)60.00mA, 600.0mA±(2.0%+5d)
Resistance (manual/auto scan)600.0Ω, 6.000kΩ, 60.00kΩ, 600.0kΩ, 6.000Ω +60.00MΩ (manual only)
±(1.0%+2d)
Capacitance (manual/auto scan)6.000nF, 60.00nF, 600.0nF, 6.000μF, 60.00μF, 600.0μF, 6.000mF +10.00mF (manual only) ±(3.0%+5d)
Diod test
Open: 2V / Resolution: 0.1V / Beeper: <30mV / Test current: 0.3mA
±(10%+5d)
Continuity
Audible threshold: <30Ω / Test current: <0.3mA
-

Size: 9.1×1.4×0.8in/230×35×20mm

Weight: 7.1oz/200g

General accessories:

1. Manual

2. Probe tip (clamshell)

3. Crocodile clip

4. Fuse

5. Button batteries

DC Voltage Measurement

Caution: Do not measure DC voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter

  1. Set the function switch to the V DC/AC position
  2. Press SEL key to select the auto scan mode or the V DC mode
  3. Touch the test probe tips to the circuit under test. Be sure to observe the correct polarity
  4. Read the voltage in the display. The display will indicate the proper decimal point and value. If the polarity is reversed the display will show (-) minus before the value.

DC Voltage Measurement

AC Voltage Measurement

Warning: Risk of Electrocution. The probe tips may not be long enough to contact the live parts inside some 240V outlets for appliances because the contacts are recessed deep in the outlets. As a result, the reading may show 0 volts when the outlet actually has voltage on it. Make sure the probe tips are touching the metal contacts inside the outlet before assuming that no voltage is present.
Caution: Do not measure AC voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter.

  1. Set the function switch to the V DC/AC position
  2. Press MODE key to select the auto scan mode or the V AC mode
  3. Touch the test probe tips to the circuit under test
  4. Read the voltage in the display. The display will indicate the proper decimal point, value and symbol (AC, V, etc.).

AC Voltage Measurement

DC Current Measurement

Caution: Do not make current measurements on the 10A scale for longer than 30 seconds. Exceeding 30 seconds may cause damage to the meter and/or the test leads.

  1. Set the function switch to the mA or A DC/AC position
  2. Press SEL key to select the auto scan mode or the mA or A DC mode
  3. Remove power from the circuit under test, then open up the circuit at the point where you wish to measure current
  4. Touch the negative test probe tip to the negative side of the circuit
  5. Touch the positive test probe tip to the positive side of the circuit
  6. Apply power to the circuit
  7. Read the current in the display
  8. The display will indicate the proper decimal point, value and symbol.

DC Current Measurement

AC Current Measurement

Warning: To avoid electric shock, do not measure AC current on any circuit whose voltage exceeds 250V AC.

  1. Set the function switch to the mA or A DC/AC position
  2. Press SEL key to select the auto scan mode or the mA or A AC mode
  3. Remove power from the circuit under test then open up the circuit at the point where you wish to measure current
  4. Touch the negative test probe tip to the negative side of the circuit
  5. Touch the positive test probe tip to the positive side of the circuit
  6. Apply power to the circuit
  7. Read the current in the display
  8. The display will indicate the proper decimal point, value and symbol.

AC Current Measurement

Resistance Measurements

Warning: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements. Remove the batteries and unplug the line cords.

  1. Set the function switch to the Ω   cap position, and press SEL key to select the auto scan mode or resistance mode.
  2. Touch the test probe tips across the circuit or part under test. It is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading.
  3. Read the resistance in the display. The display will indicate the proper decimal point, value and symbol.

Resistance Measurements

Continuity Check

Warning: To avoid electric shock, never measure continuity on circuits or wires that have voltage on them.

  1. Set the function switch to the Ω   cap position, and press SEL key to select the auto scan mode or continuity mode until the Symbol appears in the display.
  2. Touch the test probe tips to the circuit or wire you wish to check.
  3. lf the resistance is less than approximately 30Ω, the audible signal will sound. The display will also show the actual resistance.

Continuity Check

Diode Test

Warning: To avoid electric shock, do not test any diode that has voltage on it.

  1. Set the function switch to the Ω   cap position, and press MODE key To select the auto scan mode or diode mode until the symbol appears in the display.
  2. Touch the test probe tips to the diode or semiconductor junction you wish to test. Note the meter reading.
  3. Reverse the probe polarity by switching probe position. Note this reading.
  4. The diode or junction can be evaluated as follows:
    A. lf one reading shows a value and the other reading shows OL, The diode is good.
    B. lf both readings show OL, the device is open.
    C. lf both readings are very small or 0, the device is shorted.
    Note: The value indicated in the display during the diode check is the forward voltage.

Diode Test

Capacitance Measurements

Warning: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements. Remove the batteries and unplug the line cords.

  1. Set the function switch to the Ω   cap position, and press SEL key to select the auto scan mode or capacitance mode.
  2. Touch the test probe tips across the circuit or part under test. It is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading.
  3. Read the capacitance in the display. The display will indicate the proper decimal point, value and symbol.
    Note: In order to obtain an accurate reading, a capacitor must be discharge before measurement begins. The meter has a built-in discharge mode to automatically discharge the capacitor. In discharge mode, the LCD displays "DIS.C". Discharging through the meter is quite slow. We recommend users to discharge the capacitor with some other apparatus.

Capacitance Measurements

Frequently Asked Questions

  • Does AKTAKOM AMM-1063 multimeter have auto power off function?
  • How can I deactivate Auto Power Off function of AKTAKOM AMM-1063 multimeter?

  • Does AKTAKOM AMM-1063 multimeter have auto power off function?

    Yes, it does. There is Auto Power Off function in AMM-1063: the device power automatically goes off if you do not use the device within 10 minutes. Before the multimeter powers off it will make 3 short sound signals and before the powering-off – one more long signal. Press any button to start the operation again.


    Up

    How can I deactivate Auto Power Off function of AKTAKOM AMM-1063 multimeter?

    Auto Power Off function can’t be disabled in AMM-1063 multimeter.


    Up

    AKTAKOM AAM-1063 es ideal para la solución de problemas eléctricos, con ellos se puede comprobar componentes tales como resistencias, condensadores, diodos, continuidad y fallas en un circuito.
    Todas las entradas están protegidas según la norma EN 610101-1 CATIII 600V.

    Características:

    • Selección automática de DCV o ACV, capacitancia, resistencia, continuidad y selección de diodos.
    • Monitor LCD con 6000 cuentas.
    • Régimen Auto / manual.
    • Modo de grabación de datos Hold/MAX/MIN.
    • Apagado automático.
    • Amplia gama de la capacitancia.
    • Comprobación o testeo de diodo y prueba de continuidad.

    Back to the section
     

    Please give us your feedback to help us improve our website

    * - required fields

    Choose your clamp meter!
    Site map|Privacy statement|Terms of Use & Store Policies|How to Buy|Shipping|Payment|© T&M Atlantic, Inc., 2010-2016